2007
DOI: 10.3989/revmetalm.2007.v43.i1.45
|View full text |Cite
|
Sign up to set email alerts
|

Electrodialytic separation of Cu(II) and As(V) in acidic electrolytes

Abstract: The separation of copper and arsenic from acidic electrolytes by electrodialysis was investigated at room temperature. The effect of current density and pH was studied in a batch cell during 3 hours. The kinetic parameters showed that Cu(II) transport rate was 0.75 mol/m 2 /h and the As(V) transport rate was 0.002 mol/m 2 /h. An efficient separation between Cu(II) and As(V) was achieved; generating a concentrated solution of copper with no arsenic, which was obtained independently of the electrolyte acidity an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
0
0
4

Year Published

2012
2012
2019
2019

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 7 publications
0
0
0
4
Order By: Relevance
“…Adicionalmente, se usó un ánodo de platino y otro de PbCaSn (98,6 % Pb, 0,1 % Ca y 1,3 % Sn) en algunos experimentos. Detalles sobre el acondicionamiento de membranas, los electrodos, anodizado y suministro de energía se encuentran en publicaciones previas [21][22][23] . Resumidamente, las membranas fueron acondicionadas en 50 g/l de ácido sulfúrico durante 24 h antes de ser empleadas.…”
Section: Metodología Experimentalunclassified
See 2 more Smart Citations
“…Adicionalmente, se usó un ánodo de platino y otro de PbCaSn (98,6 % Pb, 0,1 % Ca y 1,3 % Sn) en algunos experimentos. Detalles sobre el acondicionamiento de membranas, los electrodos, anodizado y suministro de energía se encuentran en publicaciones previas [21][22][23] . Resumidamente, las membranas fueron acondicionadas en 50 g/l de ácido sulfúrico durante 24 h antes de ser empleadas.…”
Section: Metodología Experimentalunclassified
“…-y un 97 % de ácido arsénico (H 3 AsO 4 ) [23] . Además, este valor nulo de Tr da cuenta de la impermeabilidad de la membrana de intercambio catiónico a especies neutras y anió-nicas.…”
Section: Oxianión H 2 Asounclassified
See 1 more Smart Citation
“…Este proceso se ha utilizado para diferentes aplicaciones que abarcan desde la recuperación de agua hasta el tratamiento de distintos efluentes [1][2][3][4][5][6][7][8][9][10] . En diferentes trabajos [11][12][13][14][15][16] se ha indicado el potencial uso de la electro diálisis en la separación y concentración de las especies de Cu (II) y As (V) en soluciones de ácido sulfúrico.…”
Section: Introductionunclassified