2016
DOI: 10.1063/1.4939201
|View full text |Cite
|
Sign up to set email alerts
|

Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

Abstract: Pinhole and CCD based quasi-optical X-ray imaging technique was applied to investigate the plasma of an Electron Cyclotron Resonance Ion Source. Spectrally integrated and energy resolved images were taken from an axial perspective. The comparison of integrated images taken of argon plasma highlights the structural changes affected by some ECRIS setting parameters, like strength of the axial magnetic confinement, RF frequency and microwave power. Photon counting analysis gives precise intensity distribution of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
55
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 38 publications
(59 citation statements)
references
References 11 publications
4
55
0
Order By: Relevance
“…SDD results revealed strong correlation between plasma and beam parameters (plasma parameters: X-ray counts, electron temperature and density; beam parameters: analysed beam intensity, average charge). The results revealed a surprisingly very good agreement between warm-electrons density fluctuations, output beam currents and the calculated electromagnetic modal density of the plasma chamber [14]. Several CCD pinhole-camera images were shown as example, pointing significant differences of the energy content and displacement of the plasma vs. microwave frequency.…”
Section: The Experimental Scenariomentioning
confidence: 74%
See 1 more Smart Citation
“…SDD results revealed strong correlation between plasma and beam parameters (plasma parameters: X-ray counts, electron temperature and density; beam parameters: analysed beam intensity, average charge). The results revealed a surprisingly very good agreement between warm-electrons density fluctuations, output beam currents and the calculated electromagnetic modal density of the plasma chamber [14]. Several CCD pinhole-camera images were shown as example, pointing significant differences of the energy content and displacement of the plasma vs. microwave frequency.…”
Section: The Experimental Scenariomentioning
confidence: 74%
“…For 12.92 GHz the emission is decreasing monotonically from ROI-1 to ROI-4. This can explain the fact that at certain frequencies there is a non-perfect correlation between the volumetric emission and the trend of the Ar 4+ current, as evidenced in our previous paper [14].…”
Section: Effect Of the Rf Frequency To The Spectrally Resolved Imagesmentioning
confidence: 77%
“…The airflow also causes change in discharge power, while breakdown voltage was found to be caused by metastable state species. 45 Voltage amplitude and gas flow rate method has also been applied to characterize plasma jet. However, this characterization method cannot effectively characterize the plasma discharge at low airflow.…”
Section: Characterization Of Plasmamentioning
confidence: 99%
“…9 Evaluation and detailed analysis of the data recorded with CCD pinhole camera are still in progress. The preliminary results coming from the pictures however are promising and shown here.…”
Section: Resultsmentioning
confidence: 99%
“…The scientific results obtained by using these two detectors are going to be published. 9 There is a major conformity in the data acquisition techniques: photos were taken in photon counting mode in both cases. Thousands of images were taken with experimentally adjusted short (milliseconds) exposure time while each pixels registered either 0 or 1 X-ray events.…”
Section: Comparison Of Experimental Techniquesmentioning
confidence: 99%