2016
DOI: 10.1088/0953-4075/49/3/034004
|View full text |Cite
|
Sign up to set email alerts
|

Electron spectroscopy of rare-gas clusters irradiated by x-ray free-electron laser pulses from SACLA

Abstract: We have measured electron energy spectra and asymmetry parameters of Ar clusters and Xe clusters illuminated by intense x-rays at 5 and 5.5 keV. A velocity map imaging spectrometer was developed for this purpose and employed at an x-ray free-electron laser facility, SACLA in Japan. The cluster size dependence and the peak fluence dependence of the electron spectra and asymmetry parameters are discussed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 45 publications
(60 reference statements)
0
13
0
Order By: Relevance
“…Figs. 2 a, 3 and 4a ) 47 . The scattering patterns are recorded on a shot-to-shot basis using an out-of-vacuum CMOS camera.…”
Section: Methodsmentioning
confidence: 99%
“…Figs. 2 a, 3 and 4a ) 47 . The scattering patterns are recorded on a shot-to-shot basis using an out-of-vacuum CMOS camera.…”
Section: Methodsmentioning
confidence: 99%
“…The fragment ions resulting from the destruction of the sample, by multiphoton x-ray absorption, were detected by a multicoincidence recoil ion momentum spectrometer [36,37] [see Fig. 1 …”
Section: Resultsmentioning
confidence: 99%
“…Any change of sample due to heating was not confirmed by 1 H NMR measurements. The ions were detected by a multicoincidence recoil ion momentum spectrometer [36,37] to measure threedimensional momenta of each fragment ion. The molecular beam was crossed with the focused XFEL beam at the reaction point, and the emitted ions were projected by electrostatic fields onto an 80-mm-diameter microchannel plate (MCP) detector, in front of a delay-line anode.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…We measured the kinetic energy spectra of the electrons and ionic fragments by using electron velocity map imaging (VMI) [21,22] and ion time-of-flight (TOF) [23][24][25][26][27] spectrometers, respectively. The electron VMI spectrometer employed was specifically designed for use at the XFEL facility so that high-energy electrons up to 1 keV could be detected.…”
mentioning
confidence: 99%