2015
DOI: 10.1007/s10967-015-4036-2
|View full text |Cite
|
Sign up to set email alerts
|

Electron stripping of Bi ions using a modified 1.4 MeV/u gas stripper with pulsed gas injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
28
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(29 citation statements)
references
References 2 publications
1
28
0
Order By: Relevance
“…As shown in [17] the measured relative charge state spectrum for jet operation as well as for pulsed gas cell with Bi beam from the HSI remains the same inside the error limits, if the applied pressure inside gas jet and gas cell is high enough to reach the maximum equilibrium charge state. A comparable absolute spectrum could be potentially reached, when the beam is matched to gas jet-/gas cellstripper target and adjacent charge separating system.…”
Section: High Intensity Beam Experiments With a Pulsed Gas Strippermentioning
confidence: 52%
See 2 more Smart Citations
“…As shown in [17] the measured relative charge state spectrum for jet operation as well as for pulsed gas cell with Bi beam from the HSI remains the same inside the error limits, if the applied pressure inside gas jet and gas cell is high enough to reach the maximum equilibrium charge state. A comparable absolute spectrum could be potentially reached, when the beam is matched to gas jet-/gas cellstripper target and adjacent charge separating system.…”
Section: High Intensity Beam Experiments With a Pulsed Gas Strippermentioning
confidence: 52%
“…Accordingly, a pulsed gas injection [17] was implemented instead of a continuous gas inlet as in the existing setup. This allows an increase of the maximum gas pressure.…”
Section: Stripping Of Heavy Ionsmentioning
confidence: 99%
See 1 more Smart Citation
“…A separate gas supply for each valve enables for high flexibility in beam operation at the UNILAC [24]. The gassupply system before the stripper can be evacuated by a piston pump.…”
Section: A Gas Strippermentioning
confidence: 99%
“…The previously existing gas stripper is based on a continuous N 2 gas-jet. In the new setup, this was replaced by a pulsed gas stripper cell, exploiting the low duty cycle operation of FAIR (≤200 μs-long beam pulses, ≤3 Hz repetition rate) [12]. The gas injection is synchronized with the pulsed timing of the accelerator.…”
Section: Introductionmentioning
confidence: 99%