1970
DOI: 10.6028/jres.074a.045
|View full text |Cite
|
Sign up to set email alerts
|

Electronic densities of states from x-ray photoelectron spectroscopy

Abstract: In x-ray photoe lectro n spectrosco py (XPS), a sample is exposed to low energy x rays (a pp rox im ately keY), and th e res ultant photoelectrons a re analyzed with hi gh precis ion for kin eti c energy. Aft er co rrection for in e las ti c scatt erin g, th e measured ph otoe lectron spectrum s hould refl ect th e va le nce ba nd density of states , as we ll a s the binding ene rgies of se ve ra l co re e lec tro ni c le vels. All features in thi s spectrum will be modul ated by a pprop ri ate photoelec tri c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

8
74
0

Year Published

1970
1970
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 140 publications
(82 citation statements)
references
References 14 publications
8
74
0
Order By: Relevance
“…The Ag 3d 5/2 and 3d 3/2 peaks occur at a BE of 367.8 and 373.8 eV, respectively, and correspond to metallic silver. [25] The result demonstrates that only one form of Ag is present in solution, in the form of Ag 0 . There is no evidence for additional components in the Ag 3d spectrum, which indicates the complete reduction of the Ag + ions in the UVirradiated TSA solution.…”
Section: Resultsmentioning
confidence: 82%
“…The Ag 3d 5/2 and 3d 3/2 peaks occur at a BE of 367.8 and 373.8 eV, respectively, and correspond to metallic silver. [25] The result demonstrates that only one form of Ag is present in solution, in the form of Ag 0 . There is no evidence for additional components in the Ag 3d spectrum, which indicates the complete reduction of the Ag + ions in the UVirradiated TSA solution.…”
Section: Resultsmentioning
confidence: 82%
“…As a result, two-magnon scattering is also lower in case of Co/Au. Furthermore, Au has a lower density of electrons in d band states at the Fermi level compared to Pt [38], which therefore contributes very weakly to the intrinsic damping. to Co/Pt.…”
Section: Discussionmentioning
confidence: 99%
“…Spectra were taken, at room temperature and in a sample chamber pumped to 'about 10-7 Torr, on a Hewlett"'Packard ESCA spectrometer .. This spectrometer 'employs monochromatiped aluminum KU 1 ,2 (1486 eV) radiation: it should in principle be possible to reduce 'the previously obtainable instrumental resolution l ,2 o'f 1.0 eV by a factor of two or more. The spectrum given below shows a d~finite improvement over earlier spectra.…”
Section: Iiexperi-mentalmentioning
confidence: 99%