Electronic state resolved PEPICO spectroscopy of pyrimidine

Abstract: Photoionization techniques, such as photoelectron spectroscopy (PES) and photoionization mass spectrometry (PIMS), are well-established and powerful methods for studying the spectroscopy of isolated bio-organic molecules and their fate under vacuum ultraviolet (VUV) irradiation. Measuring the energy selected electron leaving a molecular ion in coincidence with other particles, such as ions, can provide even deeper insights into the mechanisms of the interaction of molecules with ionizing radiation. We have thu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
41
1

Year Published

2010
2010
2016
2016

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 52 publications
(44 citation statements)
references
References 39 publications
2
41
1
Order By: Relevance
“…The limit is determined by the detector size of the ion TOF spectrometer, the length of the instrument (the drift tube is 320 mm long) and the applied electric fields in the interaction region, and corresponded to the kinetic energy of about 4 eV for N + ions under the used experimental conditions. The ion TOF spectrometer offers the time-resolving power T/ T of about 175 [21]. The sample gas was introduced into the interaction region through a hypodermic needle.…”
Section: Methodsmentioning
confidence: 99%
“…The limit is determined by the detector size of the ion TOF spectrometer, the length of the instrument (the drift tube is 320 mm long) and the applied electric fields in the interaction region, and corresponded to the kinetic energy of about 4 eV for N + ions under the used experimental conditions. The ion TOF spectrometer offers the time-resolving power T/ T of about 175 [21]. The sample gas was introduced into the interaction region through a hypodermic needle.…”
Section: Methodsmentioning
confidence: 99%
“…Photoelectron spectra were recorded with a commercial hemispherical electron energy analyzer (VG 220i) which was placed at the magic angle with respect to the polarization of the incoming synchrotron beam. 11,12 The analyzer was used with pass energies of 5 eV and 10 eV which provided a resolution of 100 meV for the spectra measured at low photon energies (25-60 eV) and a resolution of 200 meV for the spectra at 120 eV photon energy. For a pass energy of 5 eV, the transmission function was measured using the Auger spectrum of xenon 13,14 and was flat within ± 10% for electrons with kinetic energies between 13 and 35 eV and decreased for lower kinetic energies to 91% of the maximum transmission at 10 eV and 70% of the maximum transmission at 8 eV.…”
Section: A Experimentalmentioning
confidence: 99%
“…17 Mass spectra were recorded with a home-made time-offlight spectrometer and the instrument is described in detail in Ref. 11. The photon energies used were 27 eV, because it allowed using a Mg-filter with an absorption edge of 49.5 eV in order to block higher order radiation, 50 eV as intermediate photon energy still below the giant np → nd resonance in Ru 3 (CO) 12 (see below) and 120 eV which is well above all outer valence resonances.…”
Section: A Experimentalmentioning
confidence: 99%
See 1 more Smart Citation
“…The results suggest that particular products of their decomposition may influence the effectiveness of the radiosensitising action of their derivatives. The experiments are based on the photofragmentation of isolated 4(5)-and 2-nitroimidazole molecules by the tunable synchrotron radiation of the GasPhase photoemission beamline [14][15][16] at Elettra (Trieste, Italy) and the vacuum ultraviolet (VUV) radiation of a rare gas discharge lamp. 17 The setups have been described elsewhere 14,17 and more details are reported in the supplementary material.…”
mentioning
confidence: 99%