2009
DOI: 10.1007/s11434-009-0184-5
|View full text |Cite
|
Sign up to set email alerts
|

Electronic structure and chemical reaction of Ca deposition on regioregular poly(3-hexylthiophene) surfaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 19 publications
1
5
0
Order By: Relevance
“…[47] After 0.04 nm Al deposition, both the original S 2p peaks (labelled as "unreacted S") of P3HT and graphene/P3HT shift slightly to higher binding energy side by 0.1 eV, which is attributed to the downward band bending due to the electron transfer from Al to the underlying substrate films. Similar band bending phenomena have also been observed for Ca/P3HT [48,49] and Li/P3HT. [46] In addition, a new doublet feature at a binding energy of 1.5 eV lower than the original peak (the blue shaded area, labeled as "reacted S") appears (Figure 4b and 4e).…”
Section: In-situ Srpes Experiments On Al/p3ht and Al/graphene/p3ht Insupporting
confidence: 82%
“…[47] After 0.04 nm Al deposition, both the original S 2p peaks (labelled as "unreacted S") of P3HT and graphene/P3HT shift slightly to higher binding energy side by 0.1 eV, which is attributed to the downward band bending due to the electron transfer from Al to the underlying substrate films. Similar band bending phenomena have also been observed for Ca/P3HT [48,49] and Li/P3HT. [46] In addition, a new doublet feature at a binding energy of 1.5 eV lower than the original peak (the blue shaded area, labeled as "reacted S") appears (Figure 4b and 4e).…”
Section: In-situ Srpes Experiments On Al/p3ht and Al/graphene/p3ht Insupporting
confidence: 82%
“…The beamline and endstation equipment have been described in detail previously. 53,54 Briefly, this beamline is connected to a bending magnet and equipped with three gratings that cover photon energies from 10 to 250 eV with a resolving power (E/ E) > 1000. The endstation is equipped with an ARUPS 10 electron analyzer.…”
Section: Methodsmentioning
confidence: 99%
“…The endstation equipment has been described in detail previously [12,13]. Briefly, the U18 beamline is connected to a bending magnet and equipped with three gratings that cover photon energies from 10 to 250 eV with a resolving power (E/ΔE) > 1000.…”
Section: Methodsmentioning
confidence: 99%