2019
DOI: 10.1038/s41598-019-50108-0
|View full text |Cite
|
Sign up to set email alerts
|

Electronic structure of MAPbI3 and MAPbCl3: importance of band alignment

Abstract: Since their first appearance, organic-inorganic perovskite absorbers have been capturing the attention of the scientific community. While high efficiency devices highlight the importance of band level alignment, very little is known on the origin of the strong n-doping character observed in the perovskite. Here, by means of a highly accurate photoemission study, we shed light on the energy alignment in perovskite-based devices. Our results suggest that the interaction with the substrate may be the driver for t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
39
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 73 publications
(45 citation statements)
references
References 52 publications
6
39
0
Order By: Relevance
“…Here, the negative CPD contrast could be explained by a higher WF in PbI 2 as compared to the 3D perovskite due to its larger bandgap and p-type characteristics, 137,[147][148][149] in line with previous observations. 150,151 The map of the GBP sample (Fig.…”
Section: Energy and Environmental Science Accepted Manuscriptsupporting
confidence: 90%
See 1 more Smart Citation
“…Here, the negative CPD contrast could be explained by a higher WF in PbI 2 as compared to the 3D perovskite due to its larger bandgap and p-type characteristics, 137,[147][148][149] in line with previous observations. 150,151 The map of the GBP sample (Fig.…”
Section: Energy and Environmental Science Accepted Manuscriptsupporting
confidence: 90%
“…14,68 Similar shifts of the Pb 4f binding energies have previously been observed when changing the halide, i.e. for MAPbCl 3 and PbCl 2 as compared to MAPbI 3 and PbI 2 , 137,138 possibly due to the higher electronegativity of Cl as compared to I.…”
Section: Energy and Environmental Science Accepted Manuscriptsupporting
confidence: 73%
“…S19, ESI †). Here, the negative CPD contrast could be explained by a higher WF in PbI 2 as compared to the 3D perovskite due to its larger bandgap and p-type characteristics, 137,[147][148][149] in line with previous observations. 150,151 The map of the GBP sample (Fig.…”
Section: Papersupporting
confidence: 90%
“…[21] The minor shifts in the Pb 4f spectrum fall within the region of the instrumental error (around 0.1 eV). [22] Overall, the XPS spectra of the Cldoped samples overlap with the one of the pure MAPbI 3 , indicating that the doping did not alter the overall electronic structure. Considering Cl 2p, no significant signal of Cl could be detected for the Cl-doped NCs.…”
Section: Morphology Structure and Composition Of Mapbi 3 Ncsmentioning
confidence: 86%