1967
DOI: 10.3891/acta.chem.scand.21-2525
|View full text |Cite
|
Sign up to set email alerts
|

Electroorganic Preparations. XXIII. Polarography and Reduction of Cinnoline and Related Compounds.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
10
0

Year Published

1970
1970
2010
2010

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 0 publications
2
10
0
Order By: Relevance
“…Between pH 2 and pH 12 the median potential is a linear function of pH, with a slope ∂Ē /∂ p H = −0.058 ± 0.003V . This is in agreement with polarographic results [21]. The median potentials of cyclic voltammograms are equal to halfwave potentials of d.c. polarograms of cinnoline.…”
Section: Resultssupporting
confidence: 87%
See 2 more Smart Citations
“…Between pH 2 and pH 12 the median potential is a linear function of pH, with a slope ∂Ē /∂ p H = −0.058 ± 0.003V . This is in agreement with polarographic results [21]. The median potentials of cyclic voltammograms are equal to halfwave potentials of d.c. polarograms of cinnoline.…”
Section: Resultssupporting
confidence: 87%
“…It has been shown theoretically that there was no splitting of the net response if charge transfer was followed by a chemical reaction [26], and hence it can be concluded that in neutral solution the transformation of 1,2-dihydrocinnoline into 1,4-dihydrocinnoline can be neglected. Because of the similarity of responses, this conclusion applies not only to the basic electrolyte, where it is expected on the basis of the polarographic results [21], but also to the solution of pH 4.65.…”
Section: Resultsmentioning
confidence: 73%
See 1 more Smart Citation
“…In addition, pH values higher than 9.0 were avoided since the reduction of INZ occurs very closely to the electrolyte/electrode discharge. The cathodic peak potential obtained for INZ in phosphate buffer solutions at pH values ranging from 1.0 to 11.0 have presented a shift of 54 mV by pH unit to more negative values, indicating that the electrode process is influenced by protonation reactions, as observed by other authors [15,32]. The optimum pH for INZ determination was 7.0.…”
Section: Voltammetry and Electrochemical Impedance Spectroscopymentioning
confidence: 67%
“…The isoniazid content in these samples was determined by four successive additions of the isoniazid standard solution. represented by a cathodic peak at −0.98 V, which can be attributed to cleavage of the -HN-NH 2 linkage with the release of NH 3 , in a process involving two protons and two electrons, as demonstrated previously [32]. There is no peak on the reverse scan indicating that the process is an irreversible process.…”
Section: Analysis Of Inz In Human Urinementioning
confidence: 75%