1961
DOI: 10.1038/1901009a0
|View full text |Cite
|
Sign up to set email alerts
|

Electrophoretic Mobility of Cultured Mesodermal Tissue Cells

Abstract: NATURE1009 was obtained by centrifuging and redissolved in isotonic saline at an alkaline pH. Paper electrophoresis of this solution yielded spots with mobilities equal to those of human globulins, but no spots with the mobility of albumin. Paper electrophoresis of the supernatant of tho original precipitate resulted in a single spot which migrated with human albumin at pH 8•6 and pH 7•4.Selective precipitation has been of limited value as a preparative tool because of possible alterations of the proteins, bot… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
8
0

Year Published

1963
1963
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(8 citation statements)
references
References 6 publications
0
8
0
Order By: Relevance
“…Cells in regeneration were reported to possess increased amounts of sialic acid and hence negative electric charge. This was shown for mouse liver cells after partial hepatectomy (4) and for embryonic fibroblasts in culture (5). One might assume that phlebo-in circulation in these cases no longer tomy accelerates proliferation of the erythro-originates from the abnormal clone.…”
Section: Discussionmentioning
confidence: 88%
“…Cells in regeneration were reported to possess increased amounts of sialic acid and hence negative electric charge. This was shown for mouse liver cells after partial hepatectomy (4) and for embryonic fibroblasts in culture (5). One might assume that phlebo-in circulation in these cases no longer tomy accelerates proliferation of the erythro-originates from the abnormal clone.…”
Section: Discussionmentioning
confidence: 88%
“…In these cells, the changes of cell surface charges were driven primarily by the transient ion flows across the plasma membranes via ion pumps and ion channels without changing the immobile molecular composition. However, all these old methods, including single-cell electrodes and cell electrophoresis, were unable to evaluate the entire cell populations 6-11.…”
Section: Introductionmentioning
confidence: 99%
“…Cells were diverse in surface charge property, and cancer cells were greater negatively charged than normal cells. [26][27][28][29] Target cells in our study were supposed to exhibit suffi cient negative charge on cellular membrane and different cell lines should show distinctive charge density, otherwise the results would be insensitive for detection and analysis. Accordingly, three cancer cell lines (HepG2, Caski, and MCF-7) were selected as the target cells.…”
mentioning
confidence: 99%