Electrophysiological Responses in the Human S3 Nerve During Sacral Neuromodulation for Fecal Incontinence

Abstract: Intra-operative electrode placement for sacral neuromodulation (SNM) relies on visual observation of motor contractions alone, lacking complete information on neural activation from stimulation. This study aimed to determine whether electrophysiological responses can be recorded directly from the S3 sacral nerve during therapeutic SNM in patients with fecal incontinence, and to characterize such responses in order to better understand the mechanism of action (MOA) and whether stimulation is subject to changes … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…Miller et al [16] considered charge per second (average current) as a definition of dose for 10 kHz, burst and tonic stimulation. This is an excellent measure for comparing total power requirements and partially accounts for the change of threshold with frequency as described by Gmel [17]; however it is possible to construct an example that demonstrates shortcomings of this method for stimulation frequencies below 100 Hz. If we consult Table 3 from Abejón and colleagues [18], we can see that at 40 Hz and 300 µs pulse duration, the therapy threshold is 8.17 mA and thus the charge per second under those conditions is 40 × 300e −6 × 0.00817 = 98 µA.…”
Section: The History Of Dose In Scsmentioning
confidence: 99%
See 1 more Smart Citation
“…Miller et al [16] considered charge per second (average current) as a definition of dose for 10 kHz, burst and tonic stimulation. This is an excellent measure for comparing total power requirements and partially accounts for the change of threshold with frequency as described by Gmel [17]; however it is possible to construct an example that demonstrates shortcomings of this method for stimulation frequencies below 100 Hz. If we consult Table 3 from Abejón and colleagues [18], we can see that at 40 Hz and 300 µs pulse duration, the therapy threshold is 8.17 mA and thus the charge per second under those conditions is 40 × 300e −6 × 0.00817 = 98 µA.…”
Section: The History Of Dose In Scsmentioning
confidence: 99%
“…These observations suggest that ECAP amplitude is a relevant measure of dose for epidemiological studies but specific values relevant to one patient may not be appropriate for another, or even for another electrode within the same patient. [17] As a definition of dose, ECAP is not reliably transferable.…”
Section: The History Of Dose In Scsmentioning
confidence: 99%