2005
DOI: 10.1002/jps.20395
|View full text |Cite
|
Sign up to set email alerts
|

Electrostatic charge characteristics of aerosols produced from metered dose inhalers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
70
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 70 publications
(73 citation statements)
references
References 20 publications
3
70
0
Order By: Relevance
“…A modified 13 stage electrical low-pressure impactor (ELPI™, Dekati Ltd, Finland), without the corona charger, was used to measure the aerosol electrostatic charge distribution, as described previously (29,37). The pMDI was shaken for 10 s and primed to waste twice using a commercial actuator before being fitted to the actuator block with the custom built adaptor.…”
Section: Measurements Of Aerosols Electrostatic Chargementioning
confidence: 99%
“…A modified 13 stage electrical low-pressure impactor (ELPI™, Dekati Ltd, Finland), without the corona charger, was used to measure the aerosol electrostatic charge distribution, as described previously (29,37). The pMDI was shaken for 10 s and primed to waste twice using a commercial actuator before being fitted to the actuator block with the custom built adaptor.…”
Section: Measurements Of Aerosols Electrostatic Chargementioning
confidence: 99%
“…This was observed in the product-dependent charge profiles of commercial MDI aerosols. [32] Both the drug particles and propellant/excipient droplets carried electrostatic charges. [32,33] The charge profile of a HFA-134a formulation was altered by a sequential addition of absolute ethanol and dissolved beclomethasone dipropionate to the propellant.…”
Section: Metered Dose Inhalersmentioning
confidence: 99%
“…[32] Both the drug particles and propellant/excipient droplets carried electrostatic charges. [32,33] The charge profile of a HFA-134a formulation was altered by a sequential addition of absolute ethanol and dissolved beclomethasone dipropionate to the propellant. [34] Similarly, the low positive charges of HFA-134a droplets became highly negative after the addition of salbutamol sulfate particles to the MDI.…”
Section: Metered Dose Inhalersmentioning
confidence: 99%
See 1 more Smart Citation
“…Similarly, aerosols produced by commercial metered dose inhalers can produce elementary charges per drug particle that range from zero to several ten thousands (Kwok et al 2005). Experimental studies based on human airway casts and in-vivo experiments have shown that particle charge significantly affects deposition in the tracheobronchial (TB) and alveolar (Al) regions.…”
Section: Introductionmentioning
confidence: 99%