2020
DOI: 10.1007/s10792-020-01519-w
|View full text |Cite
|
Sign up to set email alerts
|

Elevated intraocular pressure causes cellular and molecular retinal injuries, advocating a more moderate intraocular pressure setting during phacoemulsification surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 54 publications
2
2
0
Order By: Relevance
“…Increases in retinal thickness after cataract surgery have been observed, and such changes are closely related to surgical injuries, IOP changes, and inflammatory reactions. 29–33 Our results agree with those reported in previous studies, with the increase in GCC thickness statistically significantly greater in group 2 ( P = .02).…”
Section: Discussionsupporting
confidence: 92%
“…Increases in retinal thickness after cataract surgery have been observed, and such changes are closely related to surgical injuries, IOP changes, and inflammatory reactions. 29–33 Our results agree with those reported in previous studies, with the increase in GCC thickness statistically significantly greater in group 2 ( P = .02).…”
Section: Discussionsupporting
confidence: 92%
“…This phenomenon has not been previously reported. Actually, loss or swelling of photoreceptors has been observed in various animal glaucoma models and in clinical glaucoma patients (Panda and Jonas, 1992;Nork et al, 2000;Choi et al, 2011;Zhao et al, 2020). Overall, our results demonstrated that repeated rapid IOP transients at 50 mmHg can cause injury to all three major retinal nuclear layers.…”
Section: Discussionsupporting
confidence: 65%
“…Eyes were fully dilated bilaterally using 1% (0.01 g/mL) tropicamide and topically anesthetized with 0.5% (5 g/L) tetracaine hydrochloride. Then a 32-gauge needle connected to a column of saline (0.9% (9 g/L) NaCl) was inserted into the anterior chamber of the right eye, as previously described (Zhao et al, 2020). The peak IOP value was set at 50 mmHg by positioning the column at the appropriate height.…”
Section: Establishment Of a Spike Iop Mouse Modelmentioning
confidence: 99%
“…Such high pressures may induce impairment of perfusion of the optic nerve, retina, and choroid [ 11 ]. A recent study of acute ocular hypertension on a mouse model, that mimics a transient IOP elevation during phacoemulsification, concluded that operating at a higher intraocular pressure (90 mmHg setting vs. 45 mmHg setting) causes cellular and molecular retinal injuries [ 12 ]. All these previous studies suggest that operating on high bottle height/ target IOP settings can negatively affect the anatomy and physiology of the eye ( Fig.…”
Section: Discussionmentioning
confidence: 99%