2020
DOI: 10.1109/tim.2019.2932177
|View full text |Cite
|
Sign up to set email alerts
|

Embedded Wideband Measurement System for Fast Impedance Spectroscopy Using Undersampling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 27 publications
0
12
0
Order By: Relevance
“…From the table, one can see that this device performs favourably in terms of the magnitude and phase accuracy as well as the frequency bandwidth. The accuracy of the device is noteworthy as the ADC is only 10 bit while the most accurate device by Munjal et al [ 15 ] uses a 12 bit ADC. The cost is also competitive when the device cost outside of South Africa is considered.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…From the table, one can see that this device performs favourably in terms of the magnitude and phase accuracy as well as the frequency bandwidth. The accuracy of the device is noteworthy as the ADC is only 10 bit while the most accurate device by Munjal et al [ 15 ] uses a 12 bit ADC. The cost is also competitive when the device cost outside of South Africa is considered.…”
Section: Resultsmentioning
confidence: 99%
“…In many of these applications, low-cost design is critical to the in situ use of impedance spectroscopy as a measuring technique. For this reason, low-cost impedance devices are of interest to the general sensors community, and there was significant development in the field of low-cost impedance spectroscopy devices [ 13 , 14 , 15 ], including our prior work on a low-cost system [ 16 , 17 ] for use in point-of-need applications. The conference paper [ 16 ] explored an EIS analytical technique by measuring concentrations of different salts in water for a potential multiplexed detection application.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…microcontrollers [219], but most commonly, the Fourier transform is used, e.g. using undersampling [220]. Another approach is based on the Groetzel filter [221]- [223].…”
Section: ) Other Digital Approachesmentioning
confidence: 99%
“…On the other hand, a second technique has been investigated based on I-U measurements and fast Fourier transform (FFT) for impedance calculation. Munjal et al [ 13 ] propose a solution with an extended frequency range until 10 MHz using the under-sampling technique and achieves a maximal standard deviation of 0.5% and 0.55° deviation in amplitude and phase relatively. Based on the same technique, Vergas et al designed a portable system for detecting abnormalities in the gastrointestinal tract in the range from 10 Hz to 1 MHz with an accuracy of 2% [ 14 ].…”
Section: Introductionmentioning
confidence: 99%