Emergency Blower-Based Ventilator with Novel-Designed Ventilation Sensor and Actuator

Abstract: The ventilator, a life-saving device for COVID-19-infected patients, especially for pneumonia patients whose lungs are infected, has overwhelmingly skyrocketed since the pandemic of COVID-19 diseases started in December 2019. As a result, many biomedical engineers have rushed to design and construct emergency ventilators, using the Ambu-bag squeezing ventilator to compensate for the insufficient ventilators supply. The Ambu-bag squeezing ventilator, however, suffers from the limitation of delivered tidal volum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…If the correction value is smaller, the better the performance of the module will be. Based on TABLE 4, it can be seen if the correction value in the measurement results of the Ventilator Tester [31][7] [16], module on Ventilator 1 is the same, namely 0.2. Meanwhile, in the Ventilator 2 measurement, the largest correction value is found in the settings of 20 LPM and 30 LPM, namely 0.4.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…If the correction value is smaller, the better the performance of the module will be. Based on TABLE 4, it can be seen if the correction value in the measurement results of the Ventilator Tester [31][7] [16], module on Ventilator 1 is the same, namely 0.2. Meanwhile, in the Ventilator 2 measurement, the largest correction value is found in the settings of 20 LPM and 30 LPM, namely 0.4.…”
Section: Resultsmentioning
confidence: 99%
“…Higher PIF may also be required in patients with obstructive pulmonary disease to reduce inspiratory time [11][12] [13], thereby increasing expiratory time and reducing the risk of auto-PEEP [14][15] [16].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…2 (13) "Mode adjustment" (automatic mode, turbo mode, emergency mode); button No. 3 (14) -"Display backlight"; light indicators: red indicator light (15) -"Accident", blue indicator light (16) -"Turbo", green indicator light (17), memory card (18), display (19) speaker (20), battery charger (21), USB connector for connecting to a PC for configuring and adjusting the software of the air purification device (22), monitoring unit (23), power supply unit (24) consisting of three batteries (25), channel (26), fan (27), controller (28), tachometer (29), surge protector (30), sensor for monitoring the presence of dust in the atmosphere of the working area (31), sensor for monitoring temperature and humidity in the atmosphere of the working area (32), sensor for monitoring the concentration of carbon dioxide in the atmosphere of the working area (33), pressure monitoring sensor in the low pressure zone (34), pressure monitoring sensors in the high pressure zone (35), temperature and humidity monitoring sensor in the high pressure zone (36), purified air heater (37) Source: S. Cheberyachko et al (2020) such a situation can occur when there is no effective pressure control system or other variable parameters.…”
Section: Methodsmentioning
confidence: 99%
“…Checks are carried out to ensure the output of the ventilator is in accordance with the settings made by the nurse on the ventilator, this check is also known as with calibration [10] [11], calibration is carried out using special tools that have been tested by the manufacturer to ensure the calibration tool has high accuracy and precision so that it can be used to determine the feasibility of a medical device to be used on patients [12], this calibration activity it is very important to do especially on tools that are often used so that the use of tools that should be a support for patients does not become a boomerang that worsens the patient's condition. And in the current condition where calibration tools are needed to support checking medical devices, especially calibration tools for ventilators [13] [14], where in the last few years they are very often used, but the lack of calibration tools to check ventilators is an obstacle that is of concern, so several studies has been done to make an emergency ventilator calibration tool with the aim of making an emergency calibration tool to check the ventilator output. However, in some of these studies there has been no retrieval and analysis to display the waveform as a parameter to validate the ventilator output [12], with this background the researcher wants to analyze the waveform as a parameter to validate the ventilator output.…”
Section: Introductionmentioning
confidence: 99%