EMI reduction by means of switching frequency modulation with variable delay in power supplies

Abstract: In this article, a new model to predict the amplitude reduction of the interference harmonics in power supplies with parallel topology is presented when the switching frequency modulation with variable delay (VDFM) technique is applied. The VDFM method consists of combining the interleaving and switching frequency modulation (SFM) techniques. The new model presented has been evaluated in a multichannel buck converter, operating with different numbers of converters when a triangular modulation profile is used. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 9 publications
0
9
0
Order By: Relevance
“…In order to quickly find EM disturbance source, on one hand, keeping the power supply and transformer units work, only make one of the units work independent of other units one by one. Finally, after repeatedly online test and analysis, the power supply unit, transformer unit and indicator unit are considered as serious power disturbance sources, the specific explanations are: (1) Voltage drop and variation ( / du dt ) will cause the emission of EM field and lead to EM disturbance of power exceeding the limit line [5]; (2) Once MOS switch circuit of indicator unit works, current changes ( / di dt ) to result in EM disturbance power emission. Solving the problem of excessive power disturbance generally applies to filtering technology.…”
Section: On-line Units Positioning and Analyzingmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to quickly find EM disturbance source, on one hand, keeping the power supply and transformer units work, only make one of the units work independent of other units one by one. Finally, after repeatedly online test and analysis, the power supply unit, transformer unit and indicator unit are considered as serious power disturbance sources, the specific explanations are: (1) Voltage drop and variation ( / du dt ) will cause the emission of EM field and lead to EM disturbance of power exceeding the limit line [5]; (2) Once MOS switch circuit of indicator unit works, current changes ( / di dt ) to result in EM disturbance power emission. Solving the problem of excessive power disturbance generally applies to filtering technology.…”
Section: On-line Units Positioning and Analyzingmentioning
confidence: 99%
“…E-mail addresses: sxrfreeman@126.com (X. Shi). M a n u s c r i p t space, it's usual to use filter to reduce EM disturbance from massage [3,4,5]. So, how to weaken and reduce the EMI from electronic circuit units is very critical to promote massage design.…”
Section: Introductionmentioning
confidence: 99%
“…From (8), in order to make SYNC high for the synchronisation external clock, signal C and E must be low. Therefore the period T EN of external clock in EN pin must be shorter than T 2 and longer than T 3 according to (5) and (7).…”
Section: Introductionmentioning
confidence: 99%
“…Frequency synchronisation can be used to operate the DC-DC converter outside a critical signal frequency band of an application [7]. The spread frequency modulation technique [8][9][10] can be taken to reduce EMI by input varying external synchronous clock control signal. In a multi-power system, frequency synchronisation can also be used to synchronise multiple DC-DC switching converters to the same frequency to reduce EMI and simplify filtering design [7].…”
Section: Introductionmentioning
confidence: 99%
“…Recently, the Variable Delay with switching Frequency Modulation (VDFM) has been presented [1][2][3]. This technique, which combines interleaving with frequency modulation, is specially intended for converters in parallel topology and shows good results in terms of conducted disturbances attenuation [4].…”
Section: Introductionmentioning