“…21 The EL spectra were recorded using a PC controlled MDR-12 monochromator with a spectral resolution of up to 0.1 nm, which corresponds to the determination accuracy for the photon energy of 0.3-0.4 meV in visible and near infrared spectral regions. 22 Measurements may be carried out with constant wavelength steps Dk ¼ 0:1 À 1 nm and up to 1700 points averaged over up to 25 measurements at each point. Phase sensitive detection provided a dynamic range of operation for the system of up to five orders of magnitude.…”
Section: Experimental Details and Sample Characterizationmentioning
confidence: 99%
“…21 The EL spectra were recorded using a PC controlled MDR-12 monochromator with a spectral resolution of up to 0.1 nm, which corresponds to the determination accuracy for the photon energy of 0.3-0.4 meV in visible and near infrared spectral regions. 22 Measurements may be carried out with constant wavelength steps Dk ¼ 0:1 À 1 nm and up to 1700 points averaged over up to 25 measurements at each point. Phase sensitive detection provided a dynamic range of operation for the system of up to five orders of magnitude.…”
Section: Experimental Details and Sample Characterizationmentioning
confidence: 99%
“…The obtained EL spectra were analyzed in the frame of a model for the two-dimensional density of states in the active region successfully used earlier for light emitting diodes based on InGaN/AlGaN/GaN heterostructures [3]. The model takes into account potential fluctuations that change a step-like two-dimensional-joint density of states, describing interband transitions, to the inverse Fermi-like function with an exponential decay on the low energy side [7].…”
Section: Resultsmentioning
confidence: 99%
“…The EL spectra at currents, I , ranging from 0.1 to 30 mA were recorded using an automated system based on a MDR-12 monochromator with a spectral resolution better than 1 Å [3]. The spectra were averaged over 3/15 events of measuring at each particular point.…”
Section: Samples and Experimental Setupmentioning
confidence: 99%
“…The automated system for the recording of EL spectra was based on a MDR-12 monochromator and provides precise measurements with a spectral resolution better than 1 Å (0.3-0.4 meV) [8]. The measurements were carried out with a step width of 1 nm and averaged over 3−15 events of measuring at each particular point.…”
Section: Samples and Experimental Setupmentioning
confidence: 99%
“…The ring is fixed in the stretching device (see Fig. 1) in a position (7) between the supporting steel tube (8) and steel tube (9) that is stretched by the force F applied to the calibrated spring (10). The uniaxial compression of samples was calibrated in dependence on F by X-ray diffraction measurements [7].…”
Section: Samples and Experimental Setupmentioning
confidence: 99%