2019
DOI: 10.11591/ijece.v9i2.pp840-850
|View full text |Cite
|
Sign up to set email alerts
|

Emulated reactance and resistance by a SSSC incorporating energy storage device

Abstract: Static Synchronous series compensator without energy storage device can exchange only reactive power with the network and can operate in limited operating range in two quadrants only. When energy storage device is connected at the DC bus of SSSC (SSSC -ES), it can also exchange real power with the network. Operating range of SSSC will be much broader and it covers all the four quadrants. However, emulated reactance and resistance by SSSC -ES is likely to affect the performance of a distance protection system. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…In this study, the two SSSC are considered as independent sources. It is necessary to involve an active power source in this type of SSSC [26]- [29]. The SSSC system can be integrated with energy storage (ES) system [26], [27].…”
Section: Problem Formulation For Sssc Devices Optimal Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, the two SSSC are considered as independent sources. It is necessary to involve an active power source in this type of SSSC [26]- [29]. The SSSC system can be integrated with energy storage (ES) system [26], [27].…”
Section: Problem Formulation For Sssc Devices Optimal Controlmentioning
confidence: 99%
“…It is necessary to involve an active power source in this type of SSSC [26]- [29]. The SSSC system can be integrated with energy storage (ES) system [26], [27]. The integration of energy storage system enables to control the SSSC in the four power quadrant planes [28].…”
Section: Problem Formulation For Sssc Devices Optimal Controlmentioning
confidence: 99%
“…The FACTs can mitigate electrical power problems in different conditions (steady-state, transient, and post transient steady-state) [1][2][3][4]. It can be classified into four types, the first type is shunt controllers such as static synchronous compensator (STATCOM), the second type is series controllers, for example, static synchronous series compensator (SSSC), the third type is a combination between the series and shunt controllers such as unified power flow controller (UPFC) and the final type is a combination between two series controllers such as interline power controller (IPFC) [5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…Influence of Super conducting Magnetic Energy Storage (SMES) with SSSC and Unified Power Flow Controller on the performance of line protection relay is reported in [8], [9]. Reactance and resistance contribution by SSSC -ES during normal condition is presented in [10]. Adaptive distance setting to avoid the mal operation of distance relay in SSSC compensated systems is described in [11].…”
Section: Introductionmentioning
confidence: 99%