Enantiodetermination of R,S-3,4-methylenedioxypyrovalerone in urine samples by high pressure in-line solid-phase extraction capillary electrophoresis-mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 31 publications
0
9
0
Order By: Relevance
“…Two different BGEs-10 mM ammonium acetate and 1 M HCOOH-were evaluated in terms of resolution. This was performed considering their compatibility with the MS system and taking into account that they are both widely employed BGEs in the determination of ATS by CE-MS [21,35,40,41]. Table 2 shows the resolution between the different ATS included in this study using the two aforementioned BGEs.…”
Section: Separation and Detection Optimizationmentioning
confidence: 99%
See 2 more Smart Citations
“…Two different BGEs-10 mM ammonium acetate and 1 M HCOOH-were evaluated in terms of resolution. This was performed considering their compatibility with the MS system and taking into account that they are both widely employed BGEs in the determination of ATS by CE-MS [21,35,40,41]. Table 2 shows the resolution between the different ATS included in this study using the two aforementioned BGEs.…”
Section: Separation and Detection Optimizationmentioning
confidence: 99%
“…The advantages of CE in chiral analyses are related to the rapid method development and its flexibility when it comes to choosing or changing the chiral selector and its concentration, since the enantioseparation is performed simply by adding this substance to the BGE [11,30,[32][33][34]. However, when a chiral CE method is combined with MS it is important to take into account that, apart from volatile and low conductivity BGEs, compatible chiral selectors to prevent source dirtying should be used since this can cause problems when low sensitivity is required [29,30,34,35]. Although CDs are the most common chiral selectors used in CE, they are nonvolatile compounds and may bring about source contamination of the MS system.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this way, no suppression of the signal was observed. Figure 1 shows the enantioseparation of racemic R,S ‐MDPV spiked to a urine sample and using an in‐line SPE‐CE‐MS [26].…”
Section: Analysis Of Drugs Of Abuse By Using Miniaturized Techniquesmentioning
confidence: 99%
“…Table 1 reports selected applications by using miniaturized techniques [26][27][28][29][30][31][32][33][34][35][36][37][38][39][40][41][42][43][44].…”
Section: Selected Applications Of Miniaturized Techniques Used For Th...mentioning
confidence: 99%