2012
DOI: 10.1016/j.biomaterials.2012.09.008
|View full text |Cite
|
Sign up to set email alerts
|

End-to-side neurorrhaphy using an electrospun PCL/collagen nerve conduit for complex peripheral motor nerve regeneration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
56
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 89 publications
(56 citation statements)
references
References 47 publications
0
56
0
Order By: Relevance
“…Although many natural (e.g. collagen) (Kemp et al, 2009;Li et al, 1991) and synthetic (Polycaprolactone (PCL), chitosan, polyglycolic acid (PGA)) (Jansen et al, 2004;Lee et al, 2012;Meek and Jansen, 2009;Yao et al, 2009) conduits have been developed in an attempt to replace the requirement for autografts, functional recovery that matches autograft levels is seldom observed (Kehoe et al, 2012).…”
Section: Introductionmentioning
confidence: 99%
“…Although many natural (e.g. collagen) (Kemp et al, 2009;Li et al, 1991) and synthetic (Polycaprolactone (PCL), chitosan, polyglycolic acid (PGA)) (Jansen et al, 2004;Lee et al, 2012;Meek and Jansen, 2009;Yao et al, 2009) conduits have been developed in an attempt to replace the requirement for autografts, functional recovery that matches autograft levels is seldom observed (Kehoe et al, 2012).…”
Section: Introductionmentioning
confidence: 99%
“…This novel NC combined the biocompatibility of the collagen with the mechanical stability of the PCL, and was successfully used to repair 0.8 cm of nerve gap, achieving similar electrophysiological and muscle reinnervation results as the nerve autograft [113]. Motor recovery was also achieved with this biomaterial's combination in the reconstruction of 1 cm of defect in the tibial branch in rats [114]. Similar outcomes were achieved with the use of poly (L-lactide-co-caprolactone) nanofiber-based NC [115].…”
Section: Improvements Of the Ncs Compositionmentioning
confidence: 85%
“…Results revealed that axonal continuity was normally recovered 8 weeks after surgery, with the muscle function recovery occurring after 1-20 weeks, and recovery of donor nerve function occurring after 20 weeks. Therefore, the use of electrospun PCL/collagen nerve conduits appeared to have great potential as materials for complex peripheral motor nerve repair [73] (Figure 4).…”
Section: Lee Et Al Utilized Electrospinning Techniques To Prepare Pcmentioning
confidence: 99%