Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms

Abstract: Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were screened to identify those who had pre- and postoperative computed tomography angiography assessments with a slice thickness of ≤2 mm. The search identified 145 patients for further analysis: 110 patients (mean age 7… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(12 citation statements)
references
References 27 publications
0
12
0
Order By: Relevance
“…Finally, de Niet et al ( 29 ) also compared Anaconda™ against Zenith. This 14-year study of 145 patients sought to evaluate the conformability of both the Anaconda™ ( n = 35) and Zenith ( n = 110) endografts.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Finally, de Niet et al ( 29 ) also compared Anaconda™ against Zenith. This 14-year study of 145 patients sought to evaluate the conformability of both the Anaconda™ ( n = 35) and Zenith ( n = 110) endografts.…”
Section: Discussionmentioning
confidence: 99%
“…The influence of different graft designs on aortic anatomy after implantation was assessed. The procedural details of both devices can be seen in Figure 8 [reproduced from de Niet et al ( 29 )]. The slight difference in procedural time was insignificant, but, on the other hand, both contrast volume and estimated blood loss were significantly less with the Anaconda™ graft.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A single-center cohort study was conducted based on prospectively collected data on complex AAA patients treated with FEVAR in a tertiary care facility in the Netherlands. 14 Patients who underwent FEVAR between 2002 and 2016 because of complex AAA configuration were extracted from the Electronic Health Records. This specific cohort was used to pursue a minimal follow-up of 5 years.…”
Section: Methodsmentioning
confidence: 99%
“…Finally, two smaller additional studies reported no 30-day deaths. 24,25 A summary of the finding in this subsection can be found in Table 1 alongside results from additional Anaconda™ studies [26][27][28][29][30][31] as well as studies investigating Zenith [32][33][34][35] (to be discussed in the section 'Competitor devices'). Saratzis et al 12 Anaconda™ N = 51 16 0 3.9 Stella et al 13 Anaconda™ N = 100 23 3.3 3.3 Rödel et al 14 Anaconda™ N = 61 24 3.3 9.8 Freyrie et al 18 Anaconda™ N = 787 − 1.2 − Karkos et al 15 Anaconda™ N = 68 29 0 20 Rödel et al 24 Anaconda™ N = 36 40 0 22 Rolls et al 25 Anaconda™ N = 13 12 0 − Freyrie et al 17 Anaconda™ N = 177 33 1.1 3.6 Dijkstra et al 16 Anaconda™ N = 25 -0 2 0 Gallitto et al 26 Anaconda™ N = 26 12 7.7 − Shahverdyan et al 27 Anaconda™ N = 48 24 4 6 Kotelis et al 28 Anaconda™ N = 39 − 8 1 8 Colgan et al 29 Anaconda™ N = 101 − 3 − Midy et al 30 Anaconda™ N = 86 24 7 21.7 de Niet et al 31 Anaconda™ N = 29 -14 19 Midy et al 19 Anaconda™ N = 176 -1.7 5.1 Tigkiropolous et al 20 Anaconda™ N = 271 72 1.1 21 de Niet et al 23 Anaconda™ N = 335 − 4.2 15.8 Pini et al 21 Anaconda™ N = 127 21 4 9 Isernia et al 22 Anaconda™ N = 260 54 0.8 5.2 Verzini et al 32 Zenith N = 610 99 0.8 7.2 Vaaramaki et al 33 Zenith N = 282 − 1.8 7 Kawamata et al 34 Zenith N = 95 50 0 23.2 Oderich et al 35 Zenith N = 67 59 1.5 10.4…”
Section: Mortality and Survivalmentioning