2017
DOI: 10.1002/dc.23883
|View full text |Cite
|
Sign up to set email alerts
|

Endoscopic ultrasound guided fine‐needle aspiration: What variables influence diagnostic yield?

Abstract: The diagnostic yield of EUS-FNA is significantly related to the presence of an on-site cytopathologist and endoscopist's skill in procuring diagnostic material.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
3
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(5 citation statements)
references
References 38 publications
1
3
0
1
Order By: Relevance
“…The level of experience of the endoscopist was also ascertained as a factor affecting the adequacy of samples obtained. Some studies attributed false-negative diagnoses to the technical difficulty in obtaining a sufficient tissue volume [13,14], which means that obtaining sufficient experience is key to achieving a good diagnostic yield [15]. In our study, a stable diagnostic yield (> 80%) was achieved after performing > 40 procedures-a finding that was compatible with previously reported learning data [16][17][18].…”
Section: Discussionsupporting
confidence: 90%
“…The level of experience of the endoscopist was also ascertained as a factor affecting the adequacy of samples obtained. Some studies attributed false-negative diagnoses to the technical difficulty in obtaining a sufficient tissue volume [13,14], which means that obtaining sufficient experience is key to achieving a good diagnostic yield [15]. In our study, a stable diagnostic yield (> 80%) was achieved after performing > 40 procedures-a finding that was compatible with previously reported learning data [16][17][18].…”
Section: Discussionsupporting
confidence: 90%
“…From the literature, other factors that may influence the diagnostic yield include the mode of anaesthesia, 27 experience of the endoscopist, 16 and specimen preparation for cytopathologic interpretation. 28…”
Section: Discussionmentioning
confidence: 99%
“…El rango óptimo de pases de cualquier lesión es de 2 a 6 en la mayoría de los estudios. En un estudio de Monhaty, et al el rango de pases de aguja varió de 1 a 14 con una media de 2.6 y una mediana de 2 18 . En un estudio de Erickson, et al el diagnóstico de masas pancreáticas, metástasis hepáticas y lesiones de ganglios linfáticos requirió 5-6 y 2-3 pases, respectivamente, en ausencia de un citopatólogo 19 .…”
Section: Discussionunclassified