2010
DOI: 10.1097/mpa.0b013e3181c5c597
|View full text |Cite
|
Sign up to set email alerts
|

Endoscopic Ultrasound-Guided Fine Needle Aspiration of Pancreatic Masses in a Veteran Population

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
9
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 5 publications
0
9
0
Order By: Relevance
“…In order to decrease the non-diagnostic rates in FNAB, many factors have been investigated within the last three decades, including USG-guided aspiration biopsies [14], [15], [16], [17], [18], [19], [20], [21], [22], the number of needle interventions [23], [24], [25], the type and width of needle [26], [27], [28], [29], [30], the experience of the physician [30], [31] and the performance of on-site assessments [32], [33]. In our study, all of these factors were investigated within the context of the FNAB performed by a surgeon and a radiologist.…”
Section: Discussionmentioning
confidence: 99%
“…In order to decrease the non-diagnostic rates in FNAB, many factors have been investigated within the last three decades, including USG-guided aspiration biopsies [14], [15], [16], [17], [18], [19], [20], [21], [22], the number of needle interventions [23], [24], [25], the type and width of needle [26], [27], [28], [29], [30], the experience of the physician [30], [31] and the performance of on-site assessments [32], [33]. In our study, all of these factors were investigated within the context of the FNAB performed by a surgeon and a radiologist.…”
Section: Discussionmentioning
confidence: 99%
“…A 25-gauge needle is therefore recommended to puncture the head of the pancreas 4 . Several studies have compared the performance characteristics of a 22-gauge needle with those of a 25-gauge FNA needle for sampling pancreatic masses, but most have failed to demonstrate superiority of either needle [8][9][10][11][12][13][14][15][16][17][18][19][20][21][22] . A recent systematic review and meta-analysis of EUS-FNA for solid pancreatic masses, including a large cohort of patients, revealed that a 25-gauge needle was more sensitive than a 22-gauge needle 23 .…”
Section: Discussionmentioning
confidence: 99%
“…Variation in adequacy most likely occurs because of the fact that FNA is a complex multistep process, and many factors have the potential to affect the overall diagnostic yield. 1 Adequacy rates can be affected by the number of needle passes, 2-4 the needle type and size, [5][6][7][8] Upon completion of this activity you will be able to:…”
mentioning
confidence: 99%