Background: Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is an emerging procedure that lacks technical standardization with limited adoption beyond expert centers. We surveyed high-volume endosonographers on the technical aspects of EUS-GE to describe how the procedure is currently performed at expert centers and identify targets for standardization.
Methods: Invitations to complete an electronic survey were distributed to 21 expert EUS practitioners at 19 U.S. centers. Respondents were surveyed on technical aspects of EUS-GE, indications, efficacy, safety, and attitudes towards the procedure.
Results: All 21 (100%) invited expert endoscopists completed the survey. Nine (42.9%) reported performing >10 EUS-GEs in the last 12 months. About half (47.6%, 10/21) puncture the target loop prior to lumen-apposing metal stent (LAMS) introduction, most often to confirm the loop is jejunum. No respondents reported guidewire placement prior to LAMS introduction. Most (71.4%, 15/21) do not use a guidewire at any time, while 28.6% (6/21) reported wire placement after distal flange deployment to secure the tract during apposition. Eight (38.1%, 8/21) reported at least one major adverse event, most commonly intraperitoneal LAMS deployment (87.5%, 7/8). Factors most often reported as advantageous for EUS-GE over enteral stenting included lack of papilla interference (33.3%, 7/21) and decreased occlusion risk (23.8%, 5/21).
Conclusions: Significant variation in performance technique for EUS-GE exists among expert U.S. endoscopists, which may hinder widespread adoption and contribute to inconsistencies in reported patient outcomes. The granularity provided by these survey results may identify areas to focus standardization efforts and guide future studies on developing an ideal EUS-GE protocol.