2011
DOI: 10.1258/vasc.2010.oa0269
|View full text |Cite
|
Sign up to set email alerts
|

Endovascular repair of the half aortic arch in pigs with an improved, single-branched stent graft system for the brachiocephalic trunk

Abstract: The objective of this study was to evaluate the feasibility of endovascular repair of half of the aortic arch in pigs using an improved, integrated, single-branched stent graft for the ascending aorta and brachiocephalic trunk (BCT). We designed an improved stent graft in an integrated fashion and deployed the stent grafts into the ascending aortas and BCT of eight pigs. The feasibility of the stent graft deployments was evaluated three months after the procedures using arteriography, computed tomography angio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 19 publications
0
2
0
Order By: Relevance
“…Based on a previous clinical study on endovascular treatment of aortic arch pathologies, 14 this unibody branched stent graft and its delivery system, named "Castor", was designed and its technical safety confirmed in animal models. 15,16 This multicentre clinical trial was designed to evaluate the feasibility of the Castor single branched stent graft in treating aortic dissections involving the LSA. A Multi-centre trial of a single branched stent graft system to treat aortic dissection (ClinicalTrials.gov identifier: NCT01914237) was conducted.…”
Section: Introductionmentioning
confidence: 99%
“…Based on a previous clinical study on endovascular treatment of aortic arch pathologies, 14 this unibody branched stent graft and its delivery system, named "Castor", was designed and its technical safety confirmed in animal models. 15,16 This multicentre clinical trial was designed to evaluate the feasibility of the Castor single branched stent graft in treating aortic dissections involving the LSA. A Multi-centre trial of a single branched stent graft system to treat aortic dissection (ClinicalTrials.gov identifier: NCT01914237) was conducted.…”
Section: Introductionmentioning
confidence: 99%
“…On the basis of the previous design of the branched stent-graft, as well as other techniques, 30,31 we designed a new stent-graft system with the assistance of the research and engineering staff of LifeTech Scientific. The Yanger stent-graft system is designed to fully adapt to the native anatomy of the aortic arch, which contrasts with previous designs.…”
Section: Discussionmentioning
confidence: 99%