2019
DOI: 10.1590/0104-6632.20190362s20180473
|View full text |Cite
|
Sign up to set email alerts
|

ENERGETIC ANALYSIS OF AN ABSORPTION CHILLER USING NH3/LiNO3 AS AN ALTERNATIVE WORKING FLUID

Abstract: This paper presents a thermodynamic model developed for a prototype absorption chiller using NH 3 / LiNO 3 with 10 kW of nominal capacity. The study was undertaken using thermodynamic modeling based on the mass and energy balance, takes the overall heat transfer coefficients into consideration and uses the characteristic equation method. First, the results obtained from the thermodynamic modeling developed were compared with those obtained from the characteristic equations of thermal power activation and the c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…The use of mixtures based on ammonia/absorbents in absorption refrigeration processes has been studied, analyzed, and implemented by several authors over the years. Theoretical and experimental studies were carried out to analyze the performance of absorption refrigeration systems, using NH 3 /H 2 O [57][58][59][60] or NH 3 /LiNO 3 [61,62] or any other absorbent with NH 3 [63][64][65][66]. These techniques were investigated on prototypes or experimental apparatus and by applying the first and second Laws of Thermodynamic, as shown in Figure 3.…”
Section: Evaluation Study Of Ammonia/absorbent Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…The use of mixtures based on ammonia/absorbents in absorption refrigeration processes has been studied, analyzed, and implemented by several authors over the years. Theoretical and experimental studies were carried out to analyze the performance of absorption refrigeration systems, using NH 3 /H 2 O [57][58][59][60] or NH 3 /LiNO 3 [61,62] or any other absorbent with NH 3 [63][64][65][66]. These techniques were investigated on prototypes or experimental apparatus and by applying the first and second Laws of Thermodynamic, as shown in Figure 3.…”
Section: Evaluation Study Of Ammonia/absorbent Systemsmentioning
confidence: 99%
“…An essential aspect in the dimensioning and manufacturing of the NH 3 /LiNO 3 working fluids for absorption refrigeration systems is the no need for rectification components and with the possibility of using solar energy as the exclusive activation source as shown [19,20,121,125]. Many factors have been considered in the selection and use of these chemical components in the working fluids, as well as the use of compact heat exchangers that use loads of relatively small mixtures, leading to the construction of smaller absorption chillers [26,27,62,126], but with capacities similar to the commercial ones [127,128].…”
Section: Final Considerations On the Absorption Refrigeration Systems...mentioning
confidence: 99%
See 1 more Smart Citation