2006
DOI: 10.1007/978-3-8351-9052-8
|View full text |Cite
|
Sign up to set email alerts
|

Energieversorgung elektrischer Bahnen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…2. Thus, the overhead contact line is protected by means of a multi-step distance protection system (21 relay) with two zones [63,65,66,[68][69][70]. This system is based on the two following premises: (i) the protection needs to be discriminative to ensure that only the two circuit breakers associated with the faulted line section are tripped; (ii) the prospective fault current levels at the SP and CP are progressively smaller and may be lower than rated current.…”
Section: -Kv Ac Rts Protectionmentioning
confidence: 99%
“…2. Thus, the overhead contact line is protected by means of a multi-step distance protection system (21 relay) with two zones [63,65,66,[68][69][70]. This system is based on the two following premises: (i) the protection needs to be discriminative to ensure that only the two circuit breakers associated with the faulted line section are tripped; (ii) the prospective fault current levels at the SP and CP are progressively smaller and may be lower than rated current.…”
Section: -Kv Ac Rts Protectionmentioning
confidence: 99%
“…That means within the valid limits the output voltage is freely adjustable [2]. Therefore it is feasible to model the power stations as constant voltage sources.…”
Section: Application Examplementioning
confidence: 99%
“…Railway vehicles may be interpreted as energy sources or sinks that are moving in an inhomogeneous network, see e.g. [2]. The network consists of catenaries or third rails that are supplied by power stations and may or may not be separated in isolated sections.…”
Section: Introductionmentioning
confidence: 99%
“…Capacitor-based reactive power sources (RPS) are an effective means to enhance electrical energy quality in traction power supply systems (TPSS) of AC railroads [1][2][3][4][5][6][7][8][9][10]. Capacitors overloads by higher harmonics (HH) currents are possible due to the presence of significant harmonic distortions in TPSS which are generated by rectifying electromotives.…”
Section: Introductionmentioning
confidence: 99%