2021
DOI: 10.1016/j.matpr.2021.07.156
|View full text |Cite
|
Sign up to set email alerts
|

Energy analysis of a mixed-mode corrugated aluminium alloy (AlMn1Cu) plate solar air heater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…Here the research concerned a non-concentrating type of solar collector used for drying purposes. Some of the literature reviewed is dedicated to evaluating the pros and cons of their proposed designs (e.g., Karim and Hawlader, 2006;Koca et al, 2008;Naphon and Kornkumjayrit, 2008;Natarajan and Sathish, 2009;El-Sebaii and Al-Snani, 2010;Hans et al, 2010;Krishnananth and Kalidasa Murugavel, 2013;Nowzari et al, 2014;Chaichan et al, 2016;Dissa et al, 2016;Sharma and Kalamkar, 2017;Farajzadeh et al, 2018;Ural, 2019;Ammar et al, 2020;Das et al, 2021;Dutta et al, 2021), and a similar comparative approach is adopted here also.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Here the research concerned a non-concentrating type of solar collector used for drying purposes. Some of the literature reviewed is dedicated to evaluating the pros and cons of their proposed designs (e.g., Karim and Hawlader, 2006;Koca et al, 2008;Naphon and Kornkumjayrit, 2008;Natarajan and Sathish, 2009;El-Sebaii and Al-Snani, 2010;Hans et al, 2010;Krishnananth and Kalidasa Murugavel, 2013;Nowzari et al, 2014;Chaichan et al, 2016;Dissa et al, 2016;Sharma and Kalamkar, 2017;Farajzadeh et al, 2018;Ural, 2019;Ammar et al, 2020;Das et al, 2021;Dutta et al, 2021), and a similar comparative approach is adopted here also.…”
Section: Introductionmentioning
confidence: 99%
“…To increase the heat transfer along the air passage, Dutta et al (2021) used a corrugated aluminum alloy plate to perform the energy analysis for forced as well as free convection systems. It was noticed that an increase in the mass flow of 33% could enhance the thermal efficiency of the system by 27%, although the temperature of the working fluid dropped considerably at the outlet of the collector.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the temperature of the air at the outlet was significantly reduced. The analysis was merely based on a quantitative approach to examine the solar air heater without incorporating the simultaneous effect of pressure and temperature across the parallel plate, despite using a mixed-mode system [1]. Another work involved the thermodynamic study of textile-based solar air collectors (TB-SAC), and it was seen that the exergy of the system was increased by 32% as compared to the flat plate solar air collector.…”
Section: Introductionmentioning
confidence: 99%