Energy assessment and environmental impact analysis of an R134a/R744 cascade refrigeration plant upgraded with the low-GWP refrigerants R152a, R1234ze(E), propane (R290) and propylene (R1270)

Abstract: The European limitations associated with the use of fluorinated refrigerants have affected one of the most extended solutions used in commercial refrigeration in warm countries. Traditional cascade systems with R404A or R134a, in the high-temperature cycle, and R744 (CO 2 ), in the low side, will be prohibited from 2022 onwards unless the refrigerants used have a GWP 100 lower than 150. Since practically all the available refrigerants with low-GWP 100 are flammable, a simple but effective modification can be a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(11 citation statements)
references
References 20 publications
0
10
0
1
Order By: Relevance
“…2. Examples of energy savings in refrigeration systems [7] Refrigerant trends in Thailand have shown improvements in increasing energy efficiency and decreasing global-warming potential (GWP), as shown in Figure 3 [8,9], which is related to the hydrofluorocarbon (HFC) phase-down schedule, as shown in Figure 4 [10]. First-and secondgeneration refrigerants were composed of natural refrigerants and hydrocarbons (HCs), both of which do not impact the environment, have low GWP, and zero ozone-depletion potential (ODP) [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…2. Examples of energy savings in refrigeration systems [7] Refrigerant trends in Thailand have shown improvements in increasing energy efficiency and decreasing global-warming potential (GWP), as shown in Figure 3 [8,9], which is related to the hydrofluorocarbon (HFC) phase-down schedule, as shown in Figure 4 [10]. First-and secondgeneration refrigerants were composed of natural refrigerants and hydrocarbons (HCs), both of which do not impact the environment, have low GWP, and zero ozone-depletion potential (ODP) [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Gholamian et al 31 Studied an NH 3 /CO 2 cascade refrigeration system and carried out modeling and comprehensive evaluation. Sanchez et al 32 investigated the energy consumption analysis and environmental impact in an R134a/R744 cascade refrigeration system. It was concluded that the utilization of R744 in the low‐temperature stage had a better performance compared to other refrigerants in the cascade systems.…”
Section: Introductionmentioning
confidence: 99%
“…Refrigerant trends in Thailand have shown improvements in increasing energy efficiency and decreasing global-warming potential (GWP), as shown in Figure 3 [8,9], which is related to the hydrofluorocarbon (HFC) phase-down schedule, as shown in Figure 4 [10]. First-and second-generation refrigerants were composed of natural refrigerants and hydrocarbons (HCs), both of which do not impact the environment, have low GWP, and zero ozonedepletion potential (ODP) [11][12][13].…”
Section: Introductionmentioning
confidence: 99%