2019
DOI: 10.1038/s41598-019-49791-w
|View full text |Cite
|
Sign up to set email alerts
|

Energy-efficiency of Cardiomyocyte Stimulation with Rectangular Pulses

Abstract: In cardiac pacemaker design, energy expenditure is an important issue. This work aims to explore whether varying stimulation pulse configuration is a viable optimization strategy for reducing energy consumption by the pacemaker. A single cardiomyocyte was used as an experimental model. Each cardiomyocyte was stimulated with different stimulation protocols using rectangular waveforms applied in varying number, in short succession. The amplitude, the width of each pulse, and the interval between consecutive puls… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 18 publications
0
6
0
Order By: Relevance
“…Analysis of the MyoPulser-output confirmed sharp rectangular signals 9 , precisely following the settings applied by the user, pared with extensive data recording. Pulsing of living cells revealed remarkably exact contractions according to the applied parameters.…”
Section: Introductionmentioning
confidence: 75%
“…Analysis of the MyoPulser-output confirmed sharp rectangular signals 9 , precisely following the settings applied by the user, pared with extensive data recording. Pulsing of living cells revealed remarkably exact contractions according to the applied parameters.…”
Section: Introductionmentioning
confidence: 75%
“…The EGM is used to measure the local signal in the tissue level. To measure the interference of encoding signals to the EGM, we would need to (1) apply more advanced 3D topological tissue models, (2) analyze the coupling between cells, (3) identify possible multiple paths between the transmitting and receiving nano-actuators, and, ultimately, (4) consider the position and timing/synchronization issue of nano-actuators. This indicates the direction for future work in this field.…”
Section: Discussionmentioning
confidence: 99%
“…In the presence of heart muscle damage, heart conduction may be disturbed, and artificial pacemakers are needed to re-establish regular cardiac operation [1,2]. In our recent paper, we discussed state-of-the-art pacemakers, and proposed a conceptual nano-actuator-network-based leadless pacemaker to overcome limitations imposed by battery longevity [1] (Figure 1b).…”
Section: Introductionmentioning
confidence: 99%
“…The primary analysis modules can assist with automatic split of the trace on the basis of the events or some other protocol specification. In particular, it could be important for the experiments that can have hundreds of regions of interest, such as some electrophysiological recordings [12].…”
Section: Plos Computational Biologymentioning
confidence: 99%