2016 2nd International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM) 2016
DOI: 10.1109/icieam.2016.7911430
|View full text |Cite
|
Sign up to set email alerts
|

Energy efficiency of photovoltaic power plants in stand-alone power supply systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…of nominal one, undergoes maximum relative error of stabilization module of equivalent load eqv Z equal to 10% and equivalent phase ϕ eqv -17%. Such stabilization error of hydro-generator load may lead to the frequency stabilization error of the generated voltage in the range of 50 ± 2.5 Hz [6]. Applying the generator with armature winding taps enables to improve stabilization module of the plant equivalent load.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…of nominal one, undergoes maximum relative error of stabilization module of equivalent load eqv Z equal to 10% and equivalent phase ϕ eqv -17%. Such stabilization error of hydro-generator load may lead to the frequency stabilization error of the generated voltage in the range of 50 ± 2.5 Hz [6]. Applying the generator with armature winding taps enables to improve stabilization module of the plant equivalent load.…”
Section: Resultsmentioning
confidence: 99%
“…-sum of the squares of rms values of higher harmonics, 1 − U rms value of the first (fundamental) harmonic[5].According to the surveys[6], when operated synchronous generator with standard winding under the active-inductor load and the gate effective ballast, the highest output voltage distortion are Applied Mechanics and Materials Vol. 770 α = (50% of the workload dump) and equal voltage distortions of 11%, current distortions of 34 %.…”
mentioning
confidence: 99%
“…Due to all the inputs and all the outputs of the system are coupled, a decoupling operation at the plant input can be implemented using the inverse matrix of H R [13], which is denoted as J, see equation (15). Equation ( 16) shows the interaction of the control loops can be eliminated, where I e , defined as the estimated value of the current vector, is the new input of the system.…”
Section: B Quad Active Bridge Controlmentioning
confidence: 99%
“…Although it is possible to decide if the battery is charging or discharging by controlling the port current, which is already done, the ripple currents can cause severe problems, LC filters are added to the ports and a controller is designed in order to avoid abrupt changes in the current. The battery current reference value could be calculated from a management algorithm [15]. For this case, a lead-lag compensator is used.…”
Section: B Quad Active Bridge Controlmentioning
confidence: 99%
“…Graphene is a molecule which is thick, two dimensional, and one of the allotropic kinds of carbon arranged every so often in a honeycomb framework. Graphene is less expensive and use less energy in electronics like smart phones because of its superior optical and thermal properties [13].The most popular IBM exhibit graphene transistor which having special features than previous experimental transistors [14][15][16]. These transistors can perform 155 billion cycles per second and about 50% faster.…”
Section: The Wonder Materials Graphenementioning
confidence: 99%