2003
DOI: 10.1016/j.nima.2003.07.020
|View full text |Cite
|
Sign up to set email alerts
|

Energy resolution of a silicon detector with the RX64 ASIC designed for X-ray imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
1

Year Published

2005
2005
2016
2016

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 15 publications
0
4
1
Order By: Relevance
“…The energy resolution of the present detector is lower than some previously reported results on similar silicon strip detectors [14], which is, however, due mainly to the fact that we have considered a full system in this study. For instance, the small strip pitch needed for high-resolution mammography causes relatively large amounts of electronic noise and charge sharing, the double-threshold conguration adds complexity and electronic noise, and channelto-channel threshold spread reduces the energy resolution when more than one channel is considered.…”
Section: Resultscontrasting
confidence: 73%
See 1 more Smart Citation
“…The energy resolution of the present detector is lower than some previously reported results on similar silicon strip detectors [14], which is, however, due mainly to the fact that we have considered a full system in this study. For instance, the small strip pitch needed for high-resolution mammography causes relatively large amounts of electronic noise and charge sharing, the double-threshold conguration adds complexity and electronic noise, and channelto-channel threshold spread reduces the energy resolution when more than one channel is considered.…”
Section: Resultscontrasting
confidence: 73%
“…For both of the above approaches, however, the eectiveness may be impaired due to overlap of the spectra, and a limited exibility in choice of spectra and energy levels. In recent years, photon-counting silicon detectors with high intrinsic energy resolution and, in principle, an unlimited number of energy levels (electronic spectrum-splitting) have been introduced as another option [9,10,13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Among available semiconductor detectors, those with a single chemical element, such as silicon (Si) or germanium (Ge), are most frequently used in nuclear medicine [18,19]. However, the low atomic number of Si leads to low absorption efficiency, due to low stopping power for high-energy gamma-ray photons, and Ge has major limitations, such as a narrow band-gap energy which is useful only at cryogenic temperatures [20,21].…”
Section: Pid 350 Cdte Psdmentioning
confidence: 99%
“…One of the most important application of radiation detectors is found in medical physics. Our research group has been working on the research and development of semiconducting and scintillating detector based systems, mainly for medical imaging applications [2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%