2011
DOI: 10.1093/rpd/ncq562
|View full text |Cite
|
Sign up to set email alerts
|

Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectors

Abstract: The photon energy response of different RADOS (Mirion Technologies) personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) thermoluminescence (TL) detectors was investigated. Three types of badges were applied. The irradiation with reference photon radiation qualities N (the narrow spectrum series), and S-Cs and S-Co nuclide radiation qualities, specified in ISO 4037 [International Organization for Standardization (ISO). X and gamma reference radiations for calibrating dosemeters and doserate meter… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…The simulated geometry of the cross section of TLD-100H (element 2) produced by Geant4 code FIGURE 5. Simulated relative H p (10) response of TLD-100H compared with published experimental data (Obryk et al 2011) For photon energy 50 -120 keV, the photoelectric effect is gradually replaced by Compton scattering, thus the secondary electron spectra gradually change. This has caused the under-response to occur (Olko 2002).…”
Section: Simulation Based On a Published Workmentioning
confidence: 96%
See 3 more Smart Citations
“…The simulated geometry of the cross section of TLD-100H (element 2) produced by Geant4 code FIGURE 5. Simulated relative H p (10) response of TLD-100H compared with published experimental data (Obryk et al 2011) For photon energy 50 -120 keV, the photoelectric effect is gradually replaced by Compton scattering, thus the secondary electron spectra gradually change. This has caused the under-response to occur (Olko 2002).…”
Section: Simulation Based On a Published Workmentioning
confidence: 96%
“…In this first stage of work, the simulation was based on the Obryk's experimental work (Obryk et al 2011). The developed code used a simplified geometry to get the energy response from a single TLD chip without filter.…”
Section: Simulation Based On a Published Workmentioning
confidence: 99%
See 2 more Smart Citations
“…For verification purposes, this simulation was made based on the measured energy response of bare TLD LiF: Mg, Cu, P chip conducted by Obryk [19]. The dimension of the TLD chip used in Obryk's experiment was 4.5 mm diameter and 0.9 mm thick.…”
Section: A Simulation Modelmentioning
confidence: 99%