“…In addition, the operation of the indirect air-side economizer was possible except for a certain period when the SA temperature was set to 22.5 • C. Thus, the annual cooling-energy consumption was reduced to approximately 45% compared to that of the existing central chilled-water system. This result is similar to the annual cooling-energy saving ratio found by Ham et al [21]. This previous study analyzed the cooling-energy consumption for various indirect air-side economizers.…”
Section: Cooling Energy Consumed By Air-side Economizerssupporting
confidence: 76%
See 1 more Smart Citation
“…In addition, the operation of the indirect air-side economizer was possible except for a certain period when the SA temperature was set to 22.5 • C. Thus, the annual cooling-energy consumption was reduced to approximately 45% compared to that of the existing central chilled-water system. This result is similar to the annual cooling-energy saving ratio found by Ham et al [21]. This previous study analyzed the cooling-energy consumption for various indirect air-side economizers.…”
Section: Cooling Energy Consumed By Air-side Economizerssupporting
confidence: 76%
“…When RA* is less than 13.5 • C, the cooling load of the server rooms is handled only by the indirect air-side economizer. The heat exchanger component model described by Equations (22) and (23) is used [21].…”
Section: Indirect Air-side Economizermentioning
confidence: 99%
“…Using outdoor cold air for cooling base station is able to save a great amount of power consumption of air conditioning system during the winter and transition season. This cooling technology has alternative processes, i.e., direct fresh air cooling and isolated air heat exchanger systems [17,18].…”
Section: Introductionmentioning
confidence: 99%
“…With the assistance of active tile fans, they tried to exactly provide the airflow volume required by servers. Taking full advantages of local climate resource, some studies concentrated on saving cooling energy by air-side economizer [30,31]. Khalaj et al [32] conducted cooling energy simulations for nine different air economizers, and carried out measurement for 23 location in Australia.…”
Section: Cooling Subsystem Managementmentioning
confidence: 99%