2011
DOI: 10.1088/1748-0221/6/02/c02002
|View full text |Cite
|
Sign up to set email alerts
|

Energy weighting technique in Quantum Computed Tomography using a MPGD

Abstract: In the present work a new system for Quantum Computed Tomography was developed and tested, envisaging its application to small animals and mammography imaging. It consists of a Micro-Patterned Gas Detector based on the Micro-Hole and Strip Plate, operating in single-photon counting mode. The Micro-Hole and Strip Plate allows the storage of the position of interaction and the energy information of each single X-ray photon. With this information it is possible to select the energy range to reconstruct the images… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 10 publications
0
20
0
Order By: Relevance
“…It is the basis for methods like the Energy Weighting Technique (EWT) [3] and the Basis Material Decomposition (BMD) [4,5]. Different types of detectors have this capability, as for example the Medipix2 [6] and the MicroHole & Strip Plate (MHSP) [7,8]. The Medipix2 is a pixelated single photon counting solid state detector that comprises an adjustable energy threshold.…”
Section: Jinst 8 C03022mentioning
confidence: 99%
See 2 more Smart Citations
“…It is the basis for methods like the Energy Weighting Technique (EWT) [3] and the Basis Material Decomposition (BMD) [4,5]. Different types of detectors have this capability, as for example the Medipix2 [6] and the MicroHole & Strip Plate (MHSP) [7,8]. The Medipix2 is a pixelated single photon counting solid state detector that comprises an adjustable energy threshold.…”
Section: Jinst 8 C03022mentioning
confidence: 99%
“…These detectors allow energy selective (or even material selective) imaging that gives the possibility to enhance structures inside the object depending on their attenuation coefficients [7,9].…”
Section: Jinst 8 C03022mentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, a fine time evolution of the energy spectrum and counting rates should be provided to analyze variable or transient radiation. Multi-parameter analysis performed at very high fluence rates (410 6 photons mm À 2 s À 1 ) can be very helpful in the development of advanced energy resolved photon counting detectors, recently proposed in diagnostic medicine (computed tomography and mammography), industrial imaging and security screening [2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…Due to the increasing X-ray and gamma ray applications like synchrotron light experiments [1,2], non-destructive X-ray inspection of objects [3] and the new energy-selective imaging techniques in diagnostic X-ray medicine (mammography, computed tomography) [4,5], new spectroscopic systems with high-rate-resolution capabilities are required. Concerning the medical applications, typical diagnostic X-ray beams are characterized by photon fluence rates higher than 10 6 photons mm −2 s −1 and, in this hard environment, the development of high performance systems is still a great challenge.…”
Section: Introductionmentioning