Engineering and Performance (NEMA and Animal) of a Lower-Cost Higher-Resolution Animal PET/CT Scanner Using Photomultiplier-Quadrant-Sharing Detectors

Abstract: The dedicated murine PET (MuPET) scanner is a high-resolution, high-sensitivity, and low-cost preclinical PET camera designed and manufactured at our laboratory. In this article, we report its performance according to the NU 4-2008 standards of the National Electrical Manufacturers Association (NEMA). We also report the results of additional phantom and mouse studies. Methods: The MuPET scanner, which is integrated with a CT camera, is based on the photomultiplier-quadrant-sharing concept and comprises 180 blo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
30
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
2
2

Relationship

2
8

Authors

Journals

citations
Cited by 27 publications
(31 citation statements)
references
References 21 publications
(21 reference statements)
0
30
1
Order By: Relevance
“…To evaluate the spatial resolution, the NEMA standard mandates the use of point source scans which are reconstructed using filtered backprojection. However, basically all modern PET scanners instead use an iterative maximum likelihood expectation maximization (MLEM) algorithm for reconstruction [5,6,7,8,9,10,4,11,12,13,14,15], so a scanner's spatial resolution using filtered backprojection is not necessarily indicative of its spatial resolution for applications. While the mandated filtered backprojection is intended to benchmark the detector performance alone, we will demonstrate in the following that it disadvantages certain scanner geometries.…”
Section: Spatial Resolutionmentioning
confidence: 99%
“…To evaluate the spatial resolution, the NEMA standard mandates the use of point source scans which are reconstructed using filtered backprojection. However, basically all modern PET scanners instead use an iterative maximum likelihood expectation maximization (MLEM) algorithm for reconstruction [5,6,7,8,9,10,4,11,12,13,14,15], so a scanner's spatial resolution using filtered backprojection is not necessarily indicative of its spatial resolution for applications. While the mandated filtered backprojection is intended to benchmark the detector performance alone, we will demonstrate in the following that it disadvantages certain scanner geometries.…”
Section: Spatial Resolutionmentioning
confidence: 99%
“…Currently, the spatial resolution of most dedicated small-animal PET scanners is only 1–2 mm (14). Mice are the most frequently used animals for animal model studies of human diseases.…”
Section: Introductionmentioning
confidence: 99%
“…The PET and CT images of a mini mouse from the MuPET/CT system [7] are tested in this study. The CT images are the stitching results from three bed positions, and the PET images are from one bed position.…”
Section: Methodsmentioning
confidence: 99%