2019
DOI: 10.33552/abeb.2018.01.000510
|View full text |Cite
|
Sign up to set email alerts
|

Engineering Approaches to Prevent Blood Clotting from Medical Implants

Abstract: Injectable and/or Implantable medical devices are widely used in the treatment of diseases. Among them, vascular stents provide the medical solution to treat blood clotting. However, traditional metallic stents, even with current improvements in anticoagulation properties, have potential drawbacks in local inflammation when first implanted into the body and undesirable protein adsorption and cell adhesion after a prolonged period of time in the body. In this perspective, we discuss several engineering approach… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…Moreover, the ever-increasing problem of developing arteriosclerosis [80] in humans has contributed to the thriving development of vascular stenting procedures, thus forcing researchers to develop new solutions to prevent red blood cells from depositing on the stent surface, forming a clot and causing restenosis. In addition, due to the risk of neointima hypertrophy on the stent surface, certain solutions are expected to prevent blood clotting and neointima hyperproliferation [81,82]. Among the available scientific positions, there are reports whose results may inspire veterinary researchers on the improvement of previously used stents and their introduction into clinical practice.…”
Section: Stent Modifications and Its Possible Use In Veterinary Medicinementioning
confidence: 99%
“…Moreover, the ever-increasing problem of developing arteriosclerosis [80] in humans has contributed to the thriving development of vascular stenting procedures, thus forcing researchers to develop new solutions to prevent red blood cells from depositing on the stent surface, forming a clot and causing restenosis. In addition, due to the risk of neointima hypertrophy on the stent surface, certain solutions are expected to prevent blood clotting and neointima hyperproliferation [81,82]. Among the available scientific positions, there are reports whose results may inspire veterinary researchers on the improvement of previously used stents and their introduction into clinical practice.…”
Section: Stent Modifications and Its Possible Use In Veterinary Medicinementioning
confidence: 99%
“… 10 Despite of its efficiency, it has been associated with heparin-induced thrombocytopenia which can increase the risk of clots forming around the coated surface. 11 Many other anticoagulants including warfarin, 12 aspirin, 13 and acenocoumarol 14 have been reported to be used for biomedical implants applications to reduce the rate of thrombosis. Nevertheless, these molecules have high potency, short-term effects and chances of severe bleeding which makes them an unfavorable choice.…”
Section: Introductionmentioning