2022
DOI: 10.1109/access.2022.3149289
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced Deadbeat Control Approach for Grid-Tied Multilevel Flying Capacitors Inverter

Abstract: Date of publication xxxx 00, 0000, date of current version xxxx 00, 0000.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…To prevent short-circuits, the upper and lower switches within each cell are operated in a complementary manner. To reduce collector-emitter voltage stress, all cell voltages must be the same [22]. The averaged model describing the leg j (j ∈ {a, b, c}) of the FCI can be obtained by applying Kirchhoff's law, leading to the ( 1…”
Section: Figure 1 Schematic Illustration Of a Pmsg-based Wind Energy ...mentioning
confidence: 99%
“…To prevent short-circuits, the upper and lower switches within each cell are operated in a complementary manner. To reduce collector-emitter voltage stress, all cell voltages must be the same [22]. The averaged model describing the leg j (j ∈ {a, b, c}) of the FCI can be obtained by applying Kirchhoff's law, leading to the ( 1…”
Section: Figure 1 Schematic Illustration Of a Pmsg-based Wind Energy ...mentioning
confidence: 99%
“…Mostly, these approaches are inspired from the conventional MPC [176] and active filtering techniques [177], [178] to control the output current of the inverter. Moreover, DB-MPC have been also proposed in [174], [175] to deal with multiple objective control challenges. The authors in [179] presented a modified deadbeat current controller, based on poles placement, to control the output current and input capacitors' voltage of a hybrid multilevel switching converter.…”
Section: A Continuous Control Set Mpcmentioning
confidence: 99%
“…Most of these techniques based on primary predictive control [129] and active filtering [130]- [131] to control the output current of the voltage source inverter. However, other methods have been proposed for multi-objective control requirements [132], [137]. In addition, the DBC method is divided into two classes depending on the coordination strategy used (explicit and implicit integration functions).…”
Section: E Deadbeat Control Techniquesmentioning
confidence: 99%
“…In [132], a normalized DBC strategy has been proposed for a grid-tied 3-cell FCI (FIGURE 14) to control the two capacitors' voltages V1 and V2 around their reference values while injecting a sinusoidal current igrid to the grid with unity power factor. In the proposed controller, when the desired state is out of reach within the sampling time, the generated duty cycles calculated by ( 16) are normalized to the common base ([0 1]):…”
Section: E Deadbeat Control Techniquesmentioning
confidence: 99%