2012
DOI: 10.2116/analsci.28.267
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced Electrochemiluminescence Employed for the Selective Detection of Methyl Parathion Based on a Zirconia Nanoparticle Film Modified Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 51 publications
0
7
0
Order By: Relevance
“…ECL investigation and determination of GSK-3β were performed using the lab-built quartz ECL cell containing the prepared sensor, Pt wire, Ag wire as the working, counter, and reference electrodes, respectively. , The ECL emission of luminol was generated when an impulse voltage was applied to the working electrode, then recorded after being converted to an electrical signal by the photomultiplier tube . Afterward, 30 μL of H-buffer containing GSK-3β was spread onto the surface of sensor and allowed to equilibrate for 4 h at 35 °C to ensure complete reaction, then rinsed and dried.…”
Section: Methodsmentioning
confidence: 99%
“…ECL investigation and determination of GSK-3β were performed using the lab-built quartz ECL cell containing the prepared sensor, Pt wire, Ag wire as the working, counter, and reference electrodes, respectively. , The ECL emission of luminol was generated when an impulse voltage was applied to the working electrode, then recorded after being converted to an electrical signal by the photomultiplier tube . Afterward, 30 μL of H-buffer containing GSK-3β was spread onto the surface of sensor and allowed to equilibrate for 4 h at 35 °C to ensure complete reaction, then rinsed and dried.…”
Section: Methodsmentioning
confidence: 99%
“…Based on this, Lin's group [ 23 ] prepared an electrochemical sensor utilizing ZrO 2 as an OPs selective adsorbent for trace detection of methyl parathion. Cao et al [ 24 ] proposed an electrochemiluminescence (ECL) sensor for direct measurements of OPs pesticides based on the strong affinity of a nano ZrO 2 modified film on the electrode to the phosphoric group.…”
Section: Introductionmentioning
confidence: 99%
“…Cao et al [24] proposed an electrochemiluminescence (ECL) sensor for direct measurements of OPs pesticides based on the strong affinity of a nano ZrO 2 modified film on the electrode to the phosphoric group.…”
mentioning
confidence: 99%
“…1), is typical OPPs and most extensively used in agriculture due to its insecticidal properties, and its residues display low toxicity to human health when absorbed by the human body [10,11]. High consumption of malathion and its durability compared with other pesticides (e.g., organochlorines) have been linked to its lower potency [12][13][14]. Malathion and its commercial formulations could adversely affect the immune and central nervous systems, liver, blood, and adrenal glands [15,16].…”
Section: Introductionmentioning
confidence: 99%