2018
DOI: 10.1016/j.apsusc.2018.07.088
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced photoeletrochemical biosensing performance from rutile nanorod/anatase nanowire junction array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
12
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 29 publications
2
12
0
Order By: Relevance
“…RQ-120 shows the highest photocurrent response and the minimum arc radius in the EIS Nyquist plot, indicating its enhanced separation and transfer efficiency of photogenerated charges carriers compared to other samples. 50 Light Absorption and Band Structures. The light absorption abilities of sg-673, RQ-120, SN-120, and sg-1073 are characterized in Figure 9a.…”
Section: Effects Of Several Factors On the Photocatalyticsupporting
confidence: 91%
See 1 more Smart Citation
“…RQ-120 shows the highest photocurrent response and the minimum arc radius in the EIS Nyquist plot, indicating its enhanced separation and transfer efficiency of photogenerated charges carriers compared to other samples. 50 Light Absorption and Band Structures. The light absorption abilities of sg-673, RQ-120, SN-120, and sg-1073 are characterized in Figure 9a.…”
Section: Effects Of Several Factors On the Photocatalyticsupporting
confidence: 91%
“…Figure c,d shows the transient photocurrent response and the electrochemical impedance spectra (EIS) of sg-673, sg-1073, SN-120, and RQ-120. RQ-120 shows the highest photocurrent response and the minimum arc radius in the EIS Nyquist plot, indicating its enhanced separation and transfer efficiency of photogenerated charges carriers compared to other samples …”
Section: Resultsmentioning
confidence: 95%
“…Nanorod arrays were grown referring to the previous report. 21 In a typical process, the transparent precursor solution containing 13 mL of hydrochloric acid (38 wt%), 15 mL of deionized water and 440 mL of tetrabutyl titanate was transferred into a Teon-lined autoclave with a volume of 50 mL and the FTO substrate was introduced in the solution. The autoclave was kept in an oven at 150 C for 10 h. Aer cooling to room temperature, the FTO glass was rinsed with deionized water and ethanol several times.…”
Section: Fabrication Of Tio 2 Nanorod Arraysmentioning
confidence: 99%
“…In another example, GOx was successfully entrapped in Nafion and deposited a on a rutile nanorod/anatase nanowire TiO 2 /FTO photoelectrode [51]. The use of these TiO 2 phases (rutile and anatase) improved the PEC glucose biosensor performance as this structure facilitated the loading of the enzyme and favored the transport of electrons from the conduction band on anatase TiO 2 to that of rutile TiO 2 .…”
Section: Glucose Detectionmentioning
confidence: 99%