2012
DOI: 10.1364/oe.20.020605
|View full text |Cite
|
Sign up to set email alerts
|

Enhancement of imaging depth of two-photon microscopy using pinholes: Analytical simulation and experiments

Abstract: Achieving a greater imaging depth with two-photon fluorescence microscopy (TPFM) is mainly limited by out-of-focus fluorescence generated from both ballistic and scattered light excitation. We report on an improved signal-to-noise ratio (SNR) in a highly scattering medium as demonstrated by analytical simulation and experiments for TPFM. Our technique is based on out-of-focus rejection using a confocal pinhole. We improved the SNR by introducing the pinhole in the collection beam path. Using the radiative tran… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 25 publications
0
13
0
Order By: Relevance
“…The overall FOV and the intensity of the OS‐2P‐LSFM have complex relationships defined by the axial extend and intensity of the Bessel beam, the scanning range of the GM, the spatial collection efficiency of the OBJ1—2 , and beam clipping associated with the tilted detection (PM) .…”
Section: Resultsmentioning
confidence: 99%
“…The overall FOV and the intensity of the OS‐2P‐LSFM have complex relationships defined by the axial extend and intensity of the Bessel beam, the scanning range of the GM, the spatial collection efficiency of the OBJ1—2 , and beam clipping associated with the tilted detection (PM) .…”
Section: Resultsmentioning
confidence: 99%
“…Pinhole function as rejecting out-of focus signals, enables thin optical sectionning within thick samples [21]. …”
Section: Methodsmentioning
confidence: 99%
“…This latter situation is where non-descanned microscopy architecture -with no pinhole and large single-element detector -provides the best results. On the other hand, non-descanned detection fails in the case of high near-surface (out-of-focus) fluorescence background signal, since there is no pinhole to reject it [35,36]. In any case, as long as there are some ballistic photons, 2PE-ISM can provide a significant resolution increase.…”
Section: Introductionmentioning
confidence: 99%
“…will move this limit deeper and deeper. Moreover, one should not underestimate the benefit of having an effective optical pinhole (that is not detrimental to the SNR) in a 2PE system, as the effective working distance of a typical 2PE system is ultimately limited by near-surface (out-of-focus) fluorescence signal that the wide area detectors cannot reject [35,36]. Our simple comparison in Fig.…”
mentioning
confidence: 99%