1994
DOI: 10.2214/ajr.162.1.8273667
|View full text |Cite
|
Sign up to set email alerts
|

Enhancement of MR angiography with iron oxide: preliminary studies in whole-blood phantom and in animals.

Abstract: OBJECTIVE.We hypothesized that the previously observed Ti effect of a small

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
40
0

Year Published

1997
1997
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 86 publications
(43 citation statements)
references
References 8 publications
3
40
0
Order By: Relevance
“…For example, T 1 effects were suppressed by strong T 2 effects at MION dosages equivalent to 6 or 10 mg/kg iron. These results are in accordance with recent studies [50,67]. In conclusion, the sensitivity of T 1 -weighted MRI to determine MION- Krause/Kwong/Xiong/Gragoudas/Young induced changes of rSI is limited.…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…For example, T 1 effects were suppressed by strong T 2 effects at MION dosages equivalent to 6 or 10 mg/kg iron. These results are in accordance with recent studies [50,67]. In conclusion, the sensitivity of T 1 -weighted MRI to determine MION- Krause/Kwong/Xiong/Gragoudas/Young induced changes of rSI is limited.…”
Section: Discussionsupporting
confidence: 92%
“…These findings were in agreement with T 1 -and T 2 -weighted SI obtained with 3D-SPGR sequences [33,53,54,57]. The SI had been shown in vitro and in vivo to correlate with the concentration of MION [50] and the blood volume [33,38,53,54,57]. In the present study, increases in T 1 -and decreases in T 2 -weighted rSI were also measured at 24 h. Histology did not reveal iron staining of the intracellular or interstitial space within 0.5 h, but predominantly cytoplasmic iron staining at 24 h after the injection ( fig.…”
Section: Discussionsupporting
confidence: 88%
See 1 more Smart Citation
“…This nanoparticle was a cross-linked phospholipid nanoemulsion loaded with oleate-coated magnetite particles. The nanoemulsion reduced T2 relaxation effects, which significant improved positive T1w contrast detection at the nanomolar level 97 . Fumagillin was also loaded into the emulsions containing CIONs 98 ( Fig.…”
Section: Cardiovascular Diseasesmentioning
confidence: 99%
“…In addition, they reduce the T1 -relaxation time of blood and therefore increase blood pool signal intensity on T1-weighted scans (1 11. Iron oxides have been shown to improvc the quality of MR angiograms (M-1 by a T1-effect (12). Both effects should enhance hepatic vascular contrast, rendering iron oxides an ideal candidate for MF!…”
mentioning
confidence: 99%