2013
DOI: 10.1080/19443994.2013.764487
|View full text |Cite
|
Sign up to set email alerts
|

Enhancement of poly(phenyl sulfone) membranes with ZnO nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 44 publications
(32 citation statements)
references
References 22 publications
0
32
0
Order By: Relevance
“…However, the slight difference in mean pore size and thickness of these three membranes (see Table 3 and Figure 7) was the real reason behind these results. This occurred because the addition of PES enhanced the membrane morphology and structure, including the pore size, pore size distribution, contact angle, and surface roughness [7].…”
Section: Dye Removal Efficiency Of the Ppsu-pes Membranesmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the slight difference in mean pore size and thickness of these three membranes (see Table 3 and Figure 7) was the real reason behind these results. This occurred because the addition of PES enhanced the membrane morphology and structure, including the pore size, pore size distribution, contact angle, and surface roughness [7].…”
Section: Dye Removal Efficiency Of the Ppsu-pes Membranesmentioning
confidence: 99%
“…Membranes 2019, 9, x FOR PEER REVIEW 16 of 18 enhanced the membrane morphology and structure, including the pore size, pore size distribution, contact angle, and surface roughness [7]. The permeation fluxes were greatly enhanced with high dye removal efficiency of the simulated wastewater by the addition of PES as a polymer blend.…”
Section: Dye Removal Efficiency Of the Ppsu-pes Membranesmentioning
confidence: 99%
See 1 more Smart Citation
“…PI hollow fiber membrane was subjected to extensive surface analysis using an AFM of Angstrom Advanced Inc. (United States), model AA3000, in contact mode with a suitable silicon tip. All information about the AFM measurements was explained in details elsewhere …”
Section: Experimental Workmentioning
confidence: 99%
“…All information about the AFM measurements was explained in details elsewhere. 22,24 Pure Water Permeability (PWP) and Solutes Rejection The performance of PI hollow fiber membranes was conducted using cross-flow filtration unit as shown in Figure 1. Three hol-low fiber membranes of each type were tested under 1 bar transmembrane pressure and 600 mL/min feed flow rate.…”
Section: Preparation Of Dope Solution and Pi Hollow Fiber Nf Membranesmentioning
confidence: 99%