2013
DOI: 10.1109/tpwrs.2012.2226063
|View full text |Cite
|
Sign up to set email alerts
|

Enhancement of PV Penetration With DSTATCOM in Taipower Distribution System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
48
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 95 publications
(48 citation statements)
references
References 21 publications
0
48
0
Order By: Relevance
“…(2) The existing STATCOM works, such as References [4][5][6][7] mentioned in Section 1, have the following limitations and are less robust than the proposed method. (i) The work of Wang and Crow in [4] needs to linearize the nonlinear system before applying the feedback linearization transformation.…”
Section: Discussion Of the Proposed Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…(2) The existing STATCOM works, such as References [4][5][6][7] mentioned in Section 1, have the following limitations and are less robust than the proposed method. (i) The work of Wang and Crow in [4] needs to linearize the nonlinear system before applying the feedback linearization transformation.…”
Section: Discussion Of the Proposed Methodsmentioning
confidence: 99%
“…This may cause unexpected uncontrollability and chaotic behavior in the STATCOM dynamics. (ii) All the control gains in Chen's work [5] are fixed and not adaptive to a change of scenarios. (iii) Aziz's work in [6] addressed the application of STATCOM at the planning stage.…”
Section: Discussion Of the Proposed Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…An example of a supervision tool can be found in [21], where a probabilistic load flow method to quantify the over-voltages in a residential distribution network with high penetration of PV is presented. Also, a variety of design and control strategies to achieve operational security of distribution networks under scenarios of large PV penetration: grid-scale battery storage system design method to overcome voltage variations is presented in [22], an optimization method based on VAR compensation assisted with a communication infrastructure is proposed in [23], the coordination between static-VAR compensation and On Load Tap Changer (OLTC) are explored in [24] and the benefits of using Static Synchronous Compensator (STATCOM) for dynamic voltage regulation to avoid PV curtailments in peak situations is shown in [25].…”
Section: Outline the Available Fit Payment Plans Ie Percentage Fitmentioning
confidence: 99%
“…[4] analyze high PV penetration impacts on distribution system protection and operation. Using flexible ac transmission system and custom power devices (static VAR compensator (SVC) [5], static synchronous compensator (STATCOM) [6], distribution STATCOM (DSTATCOM) [7], superconducting magnetic energy storage (SMES) [8]), utilizing electric vehicle [9], storage system [10]- [12], and active power curtailment technique recommended in [13]- [15] are the most attractive techniques to mitigate those expected voltage violations.…”
mentioning