2017
DOI: 10.1088/1361-6560/aa6417
|View full text |Cite
|
Sign up to set email alerts
|

Enhancing ejection fraction measurement through 4D respiratory motion compensation in cardiac PET imaging

Abstract: ECG gated cardiac PET imaging measures functional parameters such as left ventricle (LV) ejection fraction (EF), providing diagnostic and prognostic information for management of patients with coronary artery disease (CAD). Respiratory motion degrades spatial resolution and affects the accuracy in measuring the LV volumes for EF calculation. The goal of this study is to systematically investigate the effect of respiratory motion correction on the estimation of end-diastolic volume (EDV), end-systolic volume (E… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 39 publications
0
2
0
Order By: Relevance
“…Motion correction of cardiac PET has been an area of active research for more than two decades , Le Meunier et al 2011, Dawood et al 2013, Lamare et al 2014, Slomka et al 2015b, Yu et al 2016 (see reviews in Rahmim et al (2013) and Slomka et al (2015a)). It is hoped that artifact-free PET images will translate into more accurate assessment of myocardial perfusion, metabolism and cardiac function, leading to improved diagnosis and staging of cardiovascular diseases (Tang et al 2017. For studies performed on standalone PET or PET/CT systems, motion has generally been tackled using the following multistep framework: First, the measured emission data are gated, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…Motion correction of cardiac PET has been an area of active research for more than two decades , Le Meunier et al 2011, Dawood et al 2013, Lamare et al 2014, Slomka et al 2015b, Yu et al 2016 (see reviews in Rahmim et al (2013) and Slomka et al (2015a)). It is hoped that artifact-free PET images will translate into more accurate assessment of myocardial perfusion, metabolism and cardiac function, leading to improved diagnosis and staging of cardiovascular diseases (Tang et al 2017. For studies performed on standalone PET or PET/CT systems, motion has generally been tackled using the following multistep framework: First, the measured emission data are gated, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…Even in patients with no overt motion, accurate quantitation of perfusion and function from cardiac PET data improves with the application of corrections not only for cardiac contraction but also for respiratory motion, an approach that has received considerable attention. 9 It can be anticipated that corrections for both types of motion will also benefit the accuracy of parameters quantified from image data acquired by stationary SPECT systems.…”
mentioning