Enhancing Transient Response and Voltage Stability of Renewable Integrated Microgrids

Abstract: Integration of renewable generation coupled with an energy storage system (ESS) in a power system increases the complexity of networks’ stability analysis and control. Therefore, an accurate stability assessment of power networks is expected to become a big challenge in the future. In this work, an effective approach to prevent power outage by controlling the source voltage of the power network is formulated to mitigate the effects of grid faults. Small signal stability studies are conducted on a renewable int… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 45 publications
0
2
0
Order By: Relevance
“…The last scenario considered the optimal allocation of the RES as presented in Figure 5, which was obtained using the proposed approach. With a view to showing the impact of the proposed approach, a basic control system was implemented in the RES, causing pessimistic stability responses in comparison to a comprehensive control system for RES [36]. It is relevant to mention that the disturbance consisted of a suddenly active power imbalance performed through the disconnection of the five highest loads within the system, i.e., load in bus 4, 8, 16, 20, and 39.…”
Section: Resultsmentioning
confidence: 99%
“…The last scenario considered the optimal allocation of the RES as presented in Figure 5, which was obtained using the proposed approach. With a view to showing the impact of the proposed approach, a basic control system was implemented in the RES, causing pessimistic stability responses in comparison to a comprehensive control system for RES [36]. It is relevant to mention that the disturbance consisted of a suddenly active power imbalance performed through the disconnection of the five highest loads within the system, i.e., load in bus 4, 8, 16, 20, and 39.…”
Section: Resultsmentioning
confidence: 99%
“…A optimal coordinated operation of a AC micro grid is to minimize the cost of operation subject, the system loss also reduces by 29.49%-31.36% in [8]. A renewable integrated IEEE 9 bus system study the effects of load-sharing devices under 6-cycle three-phase fault disturbances in [9]. A comprehensive assessment for battery energy storage system is used to reduce annual energy losses and mitigate reverse power flow and over voltage problem in [10].…”
Section: Introductionmentioning
confidence: 99%