Enthalpies for ethylbenzene, isooctane and ethylcyclohexane in the fluid state

Abstract: An electrical-matching, flow calorimeter was used to measure the enthalpies of ethylbenzene (349-551 K, 1.5-200 bar), Isooctane (358-520 K, 20-100 bar), and ethylcyclohexane (335-576 K, 20-100 bar). Water/steam calibration measurements show the apparatus capable of 0.1-0.2% precision with no detectable systematic bias.The present measurements are shown to be accurate to ±0.25% In enthalpy and ±2% in heat capacity.Literature vapor pressures, heats of vaporization, and perfect gas state enthalpies, consistent wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1997
1997
2021
2021

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…H E =-4469.000188Xb 6 +13670.6146Xb 5 Figure 24 shows how the polynomial matches the experimental data. Table 5 gives the Cp values derived by Cp= ∆ H/ ∆ T, Figure 25 shows the Cp distributions as the temperature rises.…”
Section: Apparatus For Excess Enthalpy Measurement At 25 O Cmentioning
confidence: 78%
See 1 more Smart Citation
“…H E =-4469.000188Xb 6 +13670.6146Xb 5 Figure 24 shows how the polynomial matches the experimental data. Table 5 gives the Cp values derived by Cp= ∆ H/ ∆ T, Figure 25 shows the Cp distributions as the temperature rises.…”
Section: Apparatus For Excess Enthalpy Measurement At 25 O Cmentioning
confidence: 78%
“…Castro-Gomez et al (2) presented a flow enthalpy-increment calorimeter, as A large variety of methods and procedures to measure the enthalpy increments of different kind of chemicals are available in the literature. Johnson et al (5) describe a Freon-11 boil-off calorimeter which was designed to measure the enthalpy increment of fluid up to 700 K and 200 bar. Karlsruhe (6) reports another design of flow calorimeter for the measurement of isobaric enthalpy increment (150 bar and 600 K), which can produce very good results.…”
Section: Apparatus For Incremental Enthalpy Measurementsmentioning
confidence: 99%
“…The temperature of the liquid is raised to within 5 C of the desired experimental temperature. The feed then enters the second coil placed inside the main heater oven (4) where the temperature of the liquid stream is raised to the desired temperature before it enters the vapor-liquid equilibrium cell (5). The vapor and liquid flow rates out of the VLE cell are controlled by two control valves (23,24), placed in the respective lines.…”
Section: Methodsmentioning
confidence: 99%
“…A large variety of methods and procedures to measure the enthalpy increments of different kind of chemicals are available in the literature. Johnson et al (5) describe a Freon-11 boil-off calorimeter which was designed to measure the enthalpy increment of fluid up to 700 K and 200 bar. Karlsruhe (6) reports another design of flow calorimeter for the measurement of isobaric enthalpy increment (150 bar and 600 K), which can produce very good results.…”
Section: Apparatus For Incremental Enthalpy Measurementsmentioning
confidence: 99%