2002
DOI: 10.1016/s0920-3796(02)00260-0
|View full text |Cite
|
Sign up to set email alerts
|

Entrainment behavior of activated dusts in the fusion reactor under LOVA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…• C. In both cases, inside the chamber, dry conditions were maintained in order to consider the worst situation, as the entrainment ratio decreases in the case of high value of the relative humidity [9]. A data acquisition system allows us to control the pressure, the temperature of the walls and the air flow rate.…”
Section: New Stardust Experimental Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…• C. In both cases, inside the chamber, dry conditions were maintained in order to consider the worst situation, as the entrainment ratio decreases in the case of high value of the relative humidity [9]. A data acquisition system allows us to control the pressure, the temperature of the walls and the air flow rate.…”
Section: New Stardust Experimental Setupmentioning
confidence: 99%
“…Two different sets of measurements were performed: in the first one, in order to take into account the ITER VV wall temperatures under normal operation conditions, the external walls of STARDUST were heated up to 110 • C [4] (the nominal VV wall temperature is almost 120 • C during normal operation [8]) by electrical resistances; the second set represents the MC, during which an environmental temperature was set equal to 25 • C. In both cases, inside the chamber, dry conditions were maintained in order to consider the worst situation, as the entrainment ratio decreases in the case of high value of the relative humidity [9]. A data acquisition system allows us to control the pressure, the temperature of the walls and the air flow rate.…”
Section: New Stardust Experimental Setupmentioning
confidence: 99%
“…Therefore, we measure dust entrainment by high-speed humid airflow phase change. In the previous studies [5,6], the length of the test section connected to the vessel is too short to accurately track the dust. So in this experiment, we extend the test section length up to 8 m. Graphite dusts and glass beads are used as substitutes for mobile inventory.…”
Section: Introductionmentioning
confidence: 99%