1998
DOI: 10.1016/s0168-9002(98)00788-8
|View full text |Cite
|
Sign up to set email alerts
|

Environmental control of the German radon reference chamber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…The tubing used in the set-up was the clear PVC metric tubing (Thermo Scientific/Nalgene). PVC has lower radon leakage rates than, for example, silicon rubber, norprene, or tygon (8). At SUBG, the thoron atmosphere was created in a 50.4 L Emanation Calibration Container (Saphymo GmbH).…”
Section: Methodsmentioning
confidence: 99%
“…The tubing used in the set-up was the clear PVC metric tubing (Thermo Scientific/Nalgene). PVC has lower radon leakage rates than, for example, silicon rubber, norprene, or tygon (8). At SUBG, the thoron atmosphere was created in a 50.4 L Emanation Calibration Container (Saphymo GmbH).…”
Section: Methodsmentioning
confidence: 99%
“…In 1998, radon and its progeny were measured in a radon standard chamber with different α and γ spectrophotometric systems, controlling a full set of environmental parameters such as temperature, humidity, air pressure and aerosol concentration (Honig et al, 1998). A new calibration device for measuring Rn-220 activity concentration in air was developed in 2003 (Gargioni et al, 2003).…”
Section: Federal Institute Of Physics and Technology (Ptb) Germanymentioning
confidence: 99%
“…In fact, it is rather difficult to perform a spectroscopy in open air, due to the presence of oxygen, water vapor and other electronegative gas traces. Nevertheless, some research groups have already made significant progress in this direction [3][4][5][6][7][8][9] and some results are briefly reviewed below.…”
Section: The Use Of Gas-filled Detectors For Radon Monitoring In Ambimentioning
confidence: 99%
“…He first filled a proportional counter with an air sample and then evacuated the counter after periods of time between 30 and 216 min, immediately introduced P-10 gas, a standard counting gas (argon-methane (90-10%)), to detect the alphas emitted by the radon decay products. Unfortunately, in addition to the fact that this method cannot provide on-line measurements, it has also a major drawback of fundamental importance: the equilibrium factors are not exactly known [6]. In order to make on-line medium-level measurements of radon activity, Rottger et al [7] also used a multi-wire pulse ionization chamber, similar to the one described by Baltzer.…”
Section: The Use Of Gas-filled Detectors For Radon Monitoring In Ambimentioning
confidence: 99%