1994
DOI: 10.2172/204614
|View full text |Cite
|
Sign up to set email alerts
|

EPICS Input/Output Controller (IOC) application developer`s guide. APS Release 3.12

Abstract: This report was prepared as an acwunt of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, proc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…The original read-out system allows operators to configure the slot of the VME crate, the calibration, the sample, the clock, the attenuator gain and the modulation signal threshold and perform the real time data acquisition and online data analysis. It can be divided into two parts: the server part running on MVME5100 which runs VxWorks 5) 5.4 real time operating system; and the client part created with Microsoft Visual Studio on PC 6) embedding the third-party software for the data display and processing. Its design is shown in Fig.…”
Section: The Original Read-out Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…The original read-out system allows operators to configure the slot of the VME crate, the calibration, the sample, the clock, the attenuator gain and the modulation signal threshold and perform the real time data acquisition and online data analysis. It can be divided into two parts: the server part running on MVME5100 which runs VxWorks 5) 5.4 real time operating system; and the client part created with Microsoft Visual Studio on PC 6) embedding the third-party software for the data display and processing. Its design is shown in Fig.…”
Section: The Original Read-out Systemmentioning
confidence: 99%
“…The EPICS driver connecting EPICS records with the hardware is usually divided into two parts [6]: the driver support and the device support. one DMA transfer from the electronics hardware to MVME5100 memory.…”
Section: The New Read-out Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The PC working as the front-end controller is the top-level control. The operator interface (OPI), channel access (CA) and soft input/output controller (IOC), based on the EPICS software toolkits [7], form the upper layer of the control system. The soft IOC on the upper control layer functions as a hardware controller running the device interface modules (i.e.…”
Section: The Ion Source Components and Their Control System Architecturementioning
confidence: 99%
“…The control system of BEPC is based on EPICS [2,3] , a set of open source software tools, libraries and applications developed collaboratively and used worldwide. Figure 1 illustrates the structure of the cryogenic control system at IHEP.…”
Section: Control System Overviewmentioning
confidence: 99%